Xtester-HLA510  High-Content  Oxygen  Analyzer (Special  for  oxygenerator)

Xtester-HLA510 High-Content Oxygen Analyzer (Special for oxygenerator)

2025-06-18 11:04:33  

Xtester-HLA510 High-Content Oxygen Analyzer (Special for oxygenerator)

  • Main Features :
  • Serial No. : monica0593
Contact Us For Quotation

Mail:mewoi@mewoi.com

Tel:18620373879

TesterMeter-HLA510  High-Content  Oxygen  Analyzer (Special  for  oxygenerator)

Technical Specifications:

 Measurement Principle:  Ion current (limiting current)
l Measurement Principle:Ion current (limiting current)
l Display Mode:

 LED nixie tube display

l Measurement Range: 10.00%~99.99% O2
l Measurement Accuracy: ≤±1.0%FS
l Resolution: 0.01%
l Repeatability: ≤±1.0%FS
l Response Time: T90≤ 15S
l Output Port:

 4-20mA (Non-isolated output, load resistance < 1KΩ)     0-10V.DC (Non-isolated output, load resistance>10KΩ)

1 way  of programmable  alarm  output  (Dry  contact type, maximum  load 220V/2A)

l Communication Mode: RS232 (default) or RS485
l Power Supply:AC85~264V 50/60Hz, power dissipation < 10VA
l Environment Temperature: -10℃~+50℃
l Storage Environment Humidity: <90%RH, non-condensing
l Operation Environment Humidity:<100%RH, non-condensing
l Sample Gas Temperature: 0℃~50℃
l Sampling Mode: Gas in
l Sample Gas Flow: 400~600mL/min
l Gas Inlet Pressure: 5Kpa≤ relative pressure≤200Kpa (relief valve is recommended if the pressure >200Kpa)
l Gas Outlet Pressure: Free venting (under safe conditions)
l Background Gas: N2  or other inert gas
l External Size: 110mm×190mm×252mm (H×W×D)
l Hole-Cutting Size: 90mm×170mm (H×W)
l Sensor Service Life: >4 years (under normal conditions of use)
l Gas Circuit Port: NPT 1/8 internal thread
l Installation Method: Embedded mounting

Features:

a.    Friendly communication menu allows an intuitive and convenient operation;
b.    The original imported limiting current sensor consumes no service life when the power is off, and has a long service life and is easy to maintain, etc.;
c.    No calibration gas is needed and the instrument is not affected by the oxygen content in the operation environment;

d.    With the sensor protection function, the analyzer can be turned on under occasions of

99.99% without shortening sensor’s service life;

e.    The measurement range is 10.00%~99.99%O2 ;
f.    Altitude   height  measurement  module   can  be  expanded,  preventing  the  impact  of atmospheric pressure changes on the measurement accuracy;
g.    The instrument allows multi-point fractional liner calibration, meeting the need for an accurate measurement of oxygen content among the full range;
h.    Embedded installation is easy and convenient to install and maintain;

i.     RS232 (default) or RS485 digital communication port can be selected according to clients’ requirement, to realize unidirectional or bidirectional communication with computer or other digital communication facilities.