TesterMeter-HLA510 High-Content Oxygen Analyzer (Special for oxygenerator)
Technical Specifications:
Measurement Principle: | Ion current (limiting current) |
l Measurement Principle: | Ion current (limiting current) |
l Display Mode: | LED nixie tube display |
l Measurement Range: | 10.00%~99.99% O2 |
l Measurement Accuracy: | ≤±1.0%FS |
l Resolution: | 0.01% |
l Repeatability: | ≤±1.0%FS |
l Response Time: | T90≤ 15S |
l Output Port: | 4-20mA (Non-isolated output, load resistance < 1KΩ) 0-10V.DC (Non-isolated output, load resistance>10KΩ) 1 way of programmable alarm output (Dry contact type, maximum load 220V/2A) |
l Communication Mode: | RS232 (default) or RS485 |
l Power Supply: | AC85~264V 50/60Hz, power dissipation < 10VA |
l Environment Temperature: | -10℃~+50℃ |
l Storage Environment Humidity: | <90%RH, non-condensing |
l Operation Environment Humidity: | <100%RH, non-condensing |
l Sample Gas Temperature: | 0℃~50℃ |
l Sampling Mode: | Gas in |
l Sample Gas Flow: | 400~600mL/min |
l Gas Inlet Pressure: | 5Kpa≤ relative pressure≤200Kpa (relief valve is recommended if the pressure >200Kpa) |
l Gas Outlet Pressure: | Free venting (under safe conditions) |
l Background Gas: | N2 or other inert gas |
l External Size: | 110mm×190mm×252mm (H×W×D) |
l Hole-Cutting Size: | 90mm×170mm (H×W) |
l Sensor Service Life: | >4 years (under normal conditions of use) |
l Gas Circuit Port: | NPT 1/8 internal thread |
l Installation Method: | Embedded mounting |
Features:
a. Friendly communication menu allows an intuitive and convenient operation; |
b. The original imported limiting current sensor consumes no service life when the power is off, and has a long service life and is easy to maintain, etc.; |
c. No calibration gas is needed and the instrument is not affected by the oxygen content in the operation environment; |
d. With the sensor protection function, the analyzer can be turned on under occasions of 99.99% without shortening sensor’s service life; |
e. The measurement range is 10.00%~99.99%O2 ; |
f. Altitude height measurement module can be expanded, preventing the impact of atmospheric pressure changes on the measurement accuracy; |
g. The instrument allows multi-point fractional liner calibration, meeting the need for an accurate measurement of oxygen content among the full range; |
h. Embedded installation is easy and convenient to install and maintain; |
i. RS232 (default) or RS485 digital communication port can be selected according to clients’ requirement, to realize unidirectional or bidirectional communication with computer or other digital communication facilities. |