Specifications | HM5815-5 | HM5815-10 |
Output for impulse voltage | 100V~5000V 10V steps 5%±15V | 500V~10000V 200V steps 5%±25V |
Inductance test range | >10μH | >20μH |
Impulse energy | Max 250milli-Joules | Max 500 milli-Joules |
Contents in waveform display area on LCD | 800×480 dot-matrix LCD 255×650 dot-matrix Setup parameters, standard wave and test wave, comparison result, file information, etc. |
Sample wave | Sampling rate: 200MSPS(only A series) 100MSPS, 50MSPS, 20MSPS, 10MSPS, 5MSPS, 2MSPS, 1MSPS, 500kMSPS, 200kMSPS,100kMSPS Resolution: 8bits Sampling point: 6500bytes |
Standard wave sample | Sequential cycle, single cycle, one sample (up to 32 times of sample averaging) |
Input impedance | 5MΩ |
Test speed | 6 times/sec |
Averaging rate | Number of test impulse | 1 to 32 averaging rate programmable |
Number of demagnetizing impulse | 0 to 16 averaging rate programmable |
Measurement function | Voltage, time and frequency |
Trigger mode | Internal, Manual (Foot), External and Bus |
Comparison method | AreaSize Comparison DiffZone Comparison Corona Comparison PhaseDiff Comparison |
Area size measurement accuracy | ±1% |
Area difference measurement accuracy | ±1% |
Comparison output | PASS/FAIL display Beeper alarm |
Beep mode | ON (adjust for high and low tone), OFF |
Memory | Built-in memory: 100 files USB disk memory |
Interface | HANDLER (START, STOP, PASS, NG, BUSY, EOC, etc.) RS232C USB Device USB Host LAN |