China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xtester- HT-LA411 Oxygen Analyzer on-line oxygen analysis

Xtester- HT-LA411 Oxygen Analyzer on-line oxygen analysis

2024-12-04 23:39:20  

HT LA411 Oxygen Analyzer on-line oxygen analysis

  • Main Features :
  • Serial No. : Zoe591
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

Xtester- HT-LA411 Oxygen Analyzer on-line oxygen analysis

 

Technical Parameter: 

* Measuring principle: double zirconia

* Display mode: 320×240 dot matrix color LCD

* Measuring range: 0~10/100/1000PPm/1.00%/25% O2 

* Measurement accuracy: 0~1000PPm/1.00%/25% ≤±1%FS                            

                                              0~100PPm≤±2%FS 

                                              0~10PPm≤±5%FS

* Resolution: 0.1PPm (trace)

                       0.01% (constant)

* Repeatability: ≤±1.0%FS

* Response time: T9030S 

* Output interface: 4-20mA.DC (non-isolated output, load resistance <1KΩ)   0-10V.DC (non-isolated output, load resistance>10KΩ

                               1 channel programmable dry contact type passive alarm output,the maximum capacity of the contact AC220V/2A 

                               2-way instrument status signal output

* Communication method: RS232 (default) or RS485

* Working power supply: AC85~264V 50/60Hz, power consumption <25VA

* Ambient temperature: -10~+50

* Storage environment humidity: <90%RH, non-condensing

* Working environment humidity: <100%RH, non-condensing

* Sample gas temperature: 0~60

* Sampling method: suction type

* Sample gas flow: 400~600mL/min

* Inlet pressure: -10kParelative pressure5kPa (when <5kPa, please specify the specific negative pressure value when ordering)

* Exhaust pressure: free emptying (under safe conditions)

* Background gas: N2,or other inert gases

* Size: 133mm×266mm×302mm(H×W×D)

* Hole size: 135mm×227mm (H×W), in the case of embedded installation

* Sensor life: > 5 years (under normal use conditions)

* Pneumatic interface: NPT 1/8 female thread

* Meter weight: net weight 3.9kg

* Installation method: embedded / bench-mounted

 

Instrument Features:

a.  Friendly man-machine dialogue menu, intuitive and convenient operation; 

b.   320×240 graphic dot matrix color LCD display, the display is delicate and clear; 

c.   Adopt original imported double zirconia sensor, which has the characteristics of high measurement accuracy, fast response speed and long calibration period; 

d.   Gas circuit blockage alarm and self-protection function, the sampling pump will be automatically shut down in case of gas circuit failure, effectively extending the sampling pump 

e.   Real-time test data can be displayed in the form of data or curve; 

f.   40,000 historical data storage, which can be viewed locally in the form of a list or curve, or exported through the serial port; 

g.   The instrument supports multiple Point piecewise linear calibration to meet the accurate measurement of oxygen content in the full range; 

h.   Automatic temperature compensation function to eliminate the influence of temperature changes on measurement accuracy; 

i.   Built-in imported sampling pump, long life and reliable work;

j.   Wide range AC power supply, wider application range; 

k.   According to user needs, optional RS232 (default) or RS485 data communication interface can be used for direct one-way or two-way communication with computer or other digital communication equipment.

 

 


Telephone
Email
Map
QQ Chat