China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xtester-ETCR2000 Clamp Earth Resistance Tester 0.010Ω~1000Ω,CT Size: 55mmX32mm,Ground Resistance Clamp meter
Xtester-ETCR2000 Clamp Earth Resistance Tester 0.010Ω~1000Ω,CT Size: 55mmX32mm,Ground Resistance Clamp meter
Xtester-ETCR2000 Clamp Earth Resistance Tester 0.010Ω~1000Ω,CT Size: 55mmX32mm,Ground Resistance Clamp meter
Xtester-ETCR2000 Clamp Earth Resistance Tester 0.010Ω~1000Ω,CT Size: 55mmX32mm,Ground Resistance Clamp meter
Xtester-ETCR2000 Clamp Earth Resistance Tester 0.010Ω~1000Ω,CT Size: 55mmX32mm,Ground Resistance Clamp meter
Xtester-ETCR2000 Clamp Earth Resistance Tester 0.010Ω~1000Ω,CT Size: 55mmX32mm,Ground Resistance Clamp meter

Xtester-ETCR2000 Clamp Earth Resistance Tester 0.010Ω~1000Ω,CT Size: 55mmX32mm,Ground Resistance Clamp meter

2023-09-12 12:42:34  

0.010Ω~1000Ω Ground Resistance Clamp Meter

  • Main Features : 1. Measurement of earth resistance,loop resistance 2. Measure Range: 0.010Ω~1000Ω 3. Data Storage: 99 sets 4. Alarm Threshold Setting:1-199Ω 5. Alarm Function: alarm symbol dispaly 6. CT Size: 55mmX32mm
  • Serial No. :

INTRODUCTION

Xtester-ETCR 2000 Clamp Earth Resistance Tester is a major breakthrough in traditional grounding resistance measurement. It is widely used in the grounding resistance measurement of the power, telecommunications, meteorology, oilfield, construction and the industrial and electrical equipment.

Xtester-ETCR2000 Clamp Grounding Resistance Tester, in the measurement of a grounding system with loop, does not require breaking down the grounding down lead, and no need the auxiliary electrode. It is safe, fast and simple in use.

Xtester-ETCR2000 clamp grounding resistance meter can measure ground faults which cannot be measured by traditional methods. It can be used in applications where traditional methods cannot be measured, because the Xtester-ETCR series clamp grounding resistance meter measures the combined value of grounding body resistance and grounding lead resistance. .

In addition, the C type Clamp Grounding Resistance Tester is also able to measure the leakage current and the neutral current in the grounding system.

Xtester-ETCR2000C  Accessories

  • Earth tester

  • Test ring

  • Manual

  • Warranty card/Qualification card

  • Aluminum Case

Measurement Range & Accuracy

MeasurementRangeResolutionAccuracy
Resistance

0.010Ω-0.099Ω

0.001Ω

±(1%rdg+0.01Ω)

0.10Ω-0.99Ω

0.01Ω

±(1%rdg+0.01Ω)

1.0Ω-49.9Ω

0.1Ω

±(1%rdg+0.1Ω)

50.0Ω-99.5Ω

0.5Ω

±(1.5%rdg+0.5Ω)

100Ω-199Ω

±(2%rdg+1Ω)

200Ω-395Ω

±(5%rdg+5Ω)

400-590Ω

10Ω

±(10%rdg+10Ω)

600Ω-1000Ω

20Ω

±(20%rdg+20Ω)


Technical Parameter

Function Description
Resistance Range 0.010Ω~1000Ω
Current Range 0.00mA~30.0A
Resistance Resolution 0.001Ω
Current Resolution 0.05mA
Data Storage 99 sets
Alarm Symbol Indication PressALkey to turn on / off
Alarm Threshold Setting Range Resistance:1~199Ω; Current: 1-499mA
Power Supply 6VDC 4 PCS LR6 lkaline batteries
Working Temperature -10℃-55℃;10%RH-90%RH
LCD Size 4 Digits LCD display, Screen: 47mm×28.5mm
Clamp Size 55mm×32mm
Clamp Opening Size 32mm
Tester Weight 995g
Tester Dimension 275mm×85mm×56mm
Protection Level Double insulation
Structural Feature Clamp CT
Shift Automatic shift
External Magnetic Field/Electrical Field <40A/m;<1V/m
Single Measurement Time1 second
Resistance Measurement Frequency >1KHz
Measured Current Frequency 50/60Hz Automatic
Related Series Model
ModelClamp SizeResistance RangeCurrent RangeData UploadAlarmData SaveType
Xtester-ETCR200055*32mm0.01-1000Ω//YesYesBasic
Xtester-ETCR2000A55*32mm0.01-200Ω//YesYesUtility
Xtester-ETCR2000C55*32mm0.01-1000Ω0.00mA-30.0A/YesYesMultifunction

Xtester-ETCR2000+

65*32mm0.01-1200Ω/OptionalYesYesBasic
Xtester-ETCR2000A+65*32mm0.01-200Ω/OptionalYesYesUtility
Xtester-ETCR2000B+65*32mm0.01-1200Ω/OptionalYesYesAnti-explosion
Xtester-ETCR2000C+65*32mm0.01-1200Ω0.00mA-20.0AOptionalYesYesMultifunction
Xtester-ETCR2100+Φ32mm0.01-1200Ω/OptionalYesYesBasic
Xtester-ETCR2100A+Φ32mm0.01-200Ω/OptionalYesYesUtility
Xtester-ETCR2100C+Φ32mm0.01-1200Ω0.00mA-20.0AOptionalYesYesMultifunction
Xtester-ETCR220065*32mm0.01-1500Ω0.00mA-40.0AYesYesYesHigh Performance