China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xtester-Fluke MDA-510 Motor Drive Analyzers

Xtester-Fluke MDA-510 Motor Drive Analyzers

2023-07-19 16:57:11  

Motor Drive Analyzers

  • Main Features : Guided testing with graphical step-by-step voltage and current connection diagrams makes setup and connection to variable frequency drives easier than ever Preset measurement profiles collect data based on the chosen test procedure and reduce the need for complex configuration Built-in report writing capabilities make it easy to produce professional as-found and as-left motor-drive troubleshooting reports
  • Serial No. :
Contact Us for QuotationEmail:464560351@qq.comWhatsapp: +8618620373879

Product Introduction

The Fluke MDA 510 and MDA 550 Motor-Drive Analyzers save time and eliminate the hassle of setting up complex measurements, while simplifying the troubleshooting process for variable frequency drives. Simply select a test and the step-by-step guided measurements show you where to make voltage and current connections, while the preset measurement profiles ensure you will capture all the data you need for each critical motor-drive section—from the input to the output, the DC bus, and the motor itself. From basic to advanced measurements, the MDA-500 Series has you covered, and with a built-in report generator you can quickly and easily generate as-found, and as-left reports with confidence.


The MDA-510 and MDA-550 are the ideal portable motor-drive analysis test tools and can help safely locate and troubleshoot typical problems on inverter type motor-drive systems.

Specification

Measurement Function
DC voltage (V dc)
Maximum voltage with 10:1 or 100:1 probe1000 V
Maximum resolution with 10:1 or 100:1 probe1 mV
Full scale reading999 counts
Accuracy at 4 s to 10 us/div±(3 % + 6 counts)
AC voltage (V ac)
Maximum voltage with 10:1 or 100:1 probe1000 V
Maximum resolution with 10:1 or 100:1 probe1 mV
Full scale reading999 counts
50 Hz±(3 % + 10 counts) - 0.6 %
60 Hz±(3 % + 10 counts) - 0.4 %
60 Hz to 20 kHz±(4 % + 15 counts)
20 kHz to 1 MHz±(6 % + 20 counts)
1 MHz to 25 MHz±(10 % + 20 counts)
True-rms voltage (V ac+dc)
Maximum voltage with 10:1 or 100:1 probe1000 V
Maximum resolution with 10:1 or 100:1 probe1 mV
Full scale reading1100 counts
DC to 60 Hz±(3 % + 10 counts)
60 Hz to 20 kHz±(4 % + 15 counts)
20 kHz to 1 MHz±(6 % + 20 counts)
1 MHz to 25 MHz±(10 % + 20 counts)
PWM voltage (V pwm)
PurposeTo measure on pulse width modulated signals, like motor drive inverter outputs
PrincipleReadings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency
AccuracyAs Vac+dc for sinewave signals
Peak voltage (V peak)
ModesMax peak, min peak, or pk-to-pk
Maximum voltage with 10:1 or 100:1 probe1000 V
Maximum resolution with 10:1 or 100:1 probe10 mV
Accuracy
Max peak, min peak±0.2 division
Pk-to-pk±0.4 division
Full scale reading800 counts

 

General Specification
Current (AMP) with current clamp
RangesSame as V ac, Vac+dc or V peak
Scale Factors0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50mV/A, 100 mV/A, 200 mV/A, 400 mV/A
AccuracySame as Vac, Vac+dc or V peak (add current clamp accuracy)
Frequency (Hz)
Range1.000 Hz to 500 MHz
Full scale reading999 counts
Accuracy±(0.5 % + 2 counts)
Voltage/Herz ratio (V/Hz)
PurposeTo show the measured V PWM value (see V PWM) divided by the fundamental frequency on variable ac motor speed drives
Accuracy% Vrms + % Hz
Voltage unbalance drive input
PurposeTo show the highest percentage difference of one of the phase vs average of the 3 true-rms voltages
AccuracyIndicative percentage based on Vac+dc values
Voltage unbalance drive output and motor input
PurposeTo show the highest percentage difference of one of the phase vs average of the 3 PWM voltages
AccuracyIndicative percentage based on V PWM values
Current unbalance drive input
PurposeTo show the highest percentage difference of one of the phase vs average of the 3 AC current values
AccuracyIndicative percentage based on Aac+dc values
Current unbalance drive output and motor input
PurposeTo show the highest percentage difference of one of the phase vs average of the 3 AC current values
AccuracyIndicative percentage based on A ac values
Rise and fall time
ReadingsVoltage difference (dV), time difference (dt), voltage vs time difference (dV/dt), overshoot
AccuracyAs oscilloscope accuracy
Harmonics and spectrum
HarmonicsDC to 51st
Spectrum ranges1…9 kHz, 9-150 kHz (20 MHz filter on), up to 500 MHz (voltage modulation)
Shaft voltage
Events / secondIndicative percentage based on rise and fall time (Impulse discharges) measurements
Report data capture
Number of screensTypical 50 screens can be saved in reports (depends on compression ratio)
Transfer to PCUsing 2 GB USB stick or mini-USB to USB cable and FlukeView™ 2 for ScopeMeter™ test tool
Probe settings
Voltage probe1:1, 10:1, 100:1, 1000:1, 20:1, 200:1
Current clamp0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50 mV/A, 100 mV/A, 200 mV/A, 400 mV/A
Shaft voltage probe1:1, 10:1, 100:1




Telephone
Email
Map
QQ Chat