Contact Us for Quotation | Email:464560351@qq.com | Whatsapp: +8618620373879 |
Product Introduction
The Xtester-Fluke MDA 550 Motor-Drive Analyzer saves time and eliminates the hassle of setting up complex measurements, while simplifying motor-drive troubleshooting. Simply select a test and the step-by-step guided measurements show you where to make voltage and current connections, while the preset measurement profiles ensure you will capture all the data you need for each critical motor-drive section—from the input to the output, the DC bus, and the motor itself. From basic to advanced measurements, the MDA-550 has you covered, and with a built-in report generator you can quickly and easily generate as-found, and as-left reports with confidence. The MDA-550 is the ideal portable motor-drive analysis test tool and can help safely locate and troubleshoot typical problems on inverter type motor-drive systems.
|
Specification
Measurement and Analysis Combinations | |||||
Test point | Sub group | Reading 1 | Reading 2 | Reading 3 | Reading 4 |
Motor drive input | |||||
Voltage and current | |||||
Phase-phase | V-A-Hz | V ac+dc | A ac+dc | Hz | |
V peak | V peak max | V peak min | V pk-to-pk | Crest factor | |
A peak | A peak max | A peak min | A pk-to-pk | Crest factor | |
Phase-ground | V-A-Hz | V ac+dc | A ac+dc | Hz | |
V peak | V peak max | V peak min | V pk-to-pk | Crest factor | |
A peak | A peak max | A peak min | A pk-to-pk | Crest factor | |
Voltage unbalance | Unbalance | V ac+dc | V ac+dc | V ac+dc | Unbalance |
Peak | V pk-to-pk | V pk-to-pk | V pk-to-pk | ||
Current unbalance | Unbalance | A ac+dc | A ac+dc | A ac+dc | Unbalance |
Peak | A pk-to-pk | A pk-to-pk | A pk-to-pk | ||
Motor drive DC bus | |||||
DC | V dc | V pk-to-pk | V peak max | ||
Ripple | V ac | V pk-to-pk | Hz | ||
Motor drive output | |||||
Voltage and current (filtered) | V-A-Hz | V PWM | A ac+dc | Hz | V/Hz |
V peak | V peak max | V peak min | V pk-to-pk | Crest factor | |
A peak | A peak max | A peak min | A pk-to-pk | Crest factor | |
Voltage unbalance | Unbalance | V PWM | V PWM | V PWM | Unbalance |
Peak | V pk-to-pk | V pk-to-pk | V pk-to-pk | ||
Current unbalance | Unbalance | A ac+dc | A ac+dc | A ac+dc | Unbalance |
Peak | A pk-to-pk | A pk-to-pk | A pk-to-pk | ||
Voltage modulation | |||||
Phase-phase | Zoom 1 | V PWM | V pk-to-pk | Hz | V/Hz |
Zoom 2 | V peak max | V peak min | Delta V | ||
Zoom 3 peak | V peak max | Delta V/s | Risetime peak | Overshoot | |
Zoom 3 level | Delta V | Delta V/s | Risetime level | Overshoot | |
Phase-ground | Zoom 1 | V PWM | V pk-to-pk | V peak max | V peak min |
Zoom 2 | V Peak max | V peak min | Delta V | Hz | |
Zoom 3 peak | V Peak max | Delta V/s | Risetime peak | Overshoot | |
Zoom 3 level | Delta V | Delta V/s | Risetime level | Overshoot | |
Phase-DC + | Zoom 1 | V PWM | V pk-to-pk | V Peak max | V peak min |
Zoom 2 | V peak max | V peak min | Delta V | Hz | |
Zoom 3 peak | V peak max | Delta V/s | Risetime peak | Overshoot | |
Zoom 3 level | Delta V | Delta V/s | Risetime level | Overshoot | |
Phase-DC - | Zoom 1 | V PWM | V pk-to-pk | V peak max | V peak min |
Zoom 2 | V peak max | V peak min | Delta V | Hz | |
Zoom 3 peak | V peak max | Delta V/s | Risetime peak | Overshoot | |
Zoom 3 level | Delta V | Delta V/s | Risetime level | Overshoot | |
Motor input | |||||
Voltage and current (filtered) | V-A-Hz | V PWM | A ac+dc | Hz | V/Hz |
V peak | V peak max | V peak min | V pk-to-pk | Crest factor | |
A peak | A peak max | A peak min | A pk-to-pk | Crest factor | |
Voltage unbalance | Unbalance | V PWM | V PWM | V PWM | Unbalance |
Peak | V pk-to-pk | V pk-to-pk | V pk-to-pk | ||
Current unbalance | Unbalance | A ac+dc | A ac+dc | A ac+dc | Unbalance |
Peak | A pk-to-pk | A pk-to-pk | A pk-to-pk | ||
Voltage modulation | |||||
Phase-phase | Zoom 1 | V PWM | V pk-to-pk | Hz | V/Hz |
Zoom 2 | V peak max | V peak min | Delta V | ||
Zoom 3 peak | V peak max | Delta V/s | Risetime peak | Overshoot | |
Zoom 3 level | Delta V | Delta V/s | Risetime level | Overshoot | |
Phase-ground | Zoom 1 | V PWM | V pk-to-pk | V peak max | V peak min |
Zoom 2 | V peak max | V peak min | Delta V | Hz | |
Zoom 3 peak | V peak max | Delta V/s | Risetime peak | Overshoot | |
Zoom 3 level | Delta V | Delta V/s | Risetime level | Overshoot | |
Motor shaft | |||||
Shaft voltage | Events off | V pk-to-pk | |||
Events on | Delta V | Rise/fall time | Delta V/s | Events/s | |
Motor drive input, output and motor input | |||||
Harmonics | Voltage | V ac | V fundamental | Hz fundamental | % THD |
Current | A ac | A fundamental | Hz fundamental | % THD/TDD |
Measurement Function | Specification |
DC voltage (V dc) | |
Maximum voltage with 10:1 or 100:1 probe | 1000 V |
Maximum resolution with 10:1 or 100:1 probe (voltage to ground) | 1mV / 10mV |
Full scale reading | 999 counts |
Accuracy at 4 s to 10 us/div | ± (1.5 % + 6 counts) |
True-rms voltage (V ac or V ac + dc) (with DC coupling selected) | |
Maximum voltage with 10:1 or 100:1 probe (voltage to ground) | 1000 V |
Maximum resolution with 10:1 or 100:1 probe | 1 mv / 10 mV |
Full scale reading | 999 counts |
DC to 60 Hz | ± (1.5 % + 10 counts) |
60 Hz to 20 kHz | ± (2.5 % + 15 counts) |
20 kHz to 1 MHz | ± (5 % + 20 counts) |
1 MHz to 25 MHz | ± (10 % + 20 counts) |
PWM voltage (V pwm) | |
Purpose | To measure on pulse width modulated signals, like motor drive inverter outputs |
Principle | Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency |
Accuracy | As Vac+dc for sinewave signals |
Peak voltage (V peak) | |
Modes | Max peak, min peak, or pk-to-pk |
Maximum voltage with 10:1 or 100:1 probe (voltage to ground) | 1000 V |
Maximum resolution with 10:1 or 100:1 probe | 10 mV |
Accuracy | |
Max peak, min peak | ± 0.2 division |
Pk-to-pk | ± 0.4 division |
Full scale reading | 800 counts |
Current (AMP) with current clamp | |
Ranges | Same as V ac, Vac+dc or V peak |
Scale Factors | 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50mV/A, 100 mV/A, 200 mV/A, 400 mV/A |
Accuracy | Same as Vac, Vac+dc or V peak (add current clamp accuracy) |
Frequency (Hz) | |
Range | 1.000 Hz to 500 MHz |
Full scale reading | 9999 counts |
Accuracy | ± (0.5 % + 2 counts) |
Voltage/Herz ratio (V/Hz) | |
Purpose | To show the measured V PWM value (see V PWM) divided by the fundamental frequency on vari- able ac motor speed drives |
Accuracy | % Vrms + % Hz |
Voltage unbalance drive input | |
Purpose | To show the highest percentage difference of one of the phase vs average of the 3 true-rms voltages |
Accuracy | Indicative percentage based on Vac+dc values |
Voltage unbalance drive output and motor input | |
Purpose | To show the highest percentage difference of one of the phase vs average of the 3 PWM voltages |
Accuracy | Indicative percentage based on V PWM values |
Current unbalance drive input | |
Purpose | To show the highest percentage difference of one of the phase vs average of the 3 AC current values |
Accuracy | Indicative percentage based on Aac+dc values |
Current unbalance drive output and motor input | |
Purpose | To show the highest percentage difference of one of the phase vs average of the 3 AC current values |
Accuracy | Indicative percentage based on A ac values |
Rise and fall time | |
Readings | Voltage difference (dV), time difference (dt), voltage vs time difference (dV/dt), overshoot |
Accuracy | As oscilloscope accuracy |
Harmonics and spectrum | |
Harmonics | DC to 51st |
Spectrum ranges | 1…9 kHz, 9-150 kHz (20 MHz filter on), up to 500 MHz (voltage modulation) |
Shaft voltage | |
Events / second | Indicative percentage based on rise and fall time (Impulse discharges) measurements |
Report data capture | |
Number of screens | Typical 50 screens can be saved in reports (depends on compression ratio) |
Transfer to PC | Using 32 GB or smaller 2 GB USB stick or mini-USB to USB cable or WiFi link and FlukeView™ 2 for ScopeMeter® |
Probe settings | |
Voltage Probe | 1:1, 10:1, 100:1, 1000:1, 20:1, 200:1 |
Current Clamp | 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50 mV/A, 100 mV/A, 200 mV/A, 400 mV/A |
Shaft Voltage Probe | 1:1, 10:1, 100:1 |
Safety | |
General | IEC 61010-1: Pollution Degree 2 |
Measurement | Measurement IEC 61010-2-030: CAT IV 600 V / CAT III 1000 V |
Maximum voltage between any Terminal and Earth Ground | 1000 V |
Max. input voltages | Via VPS410-II or VPS421 1000 V CAT III / 600 V CAT IV |
BNC Input | A, B, C, D directly 300 V CAT IV |
Max. Floating Voltage, test tool or test tool with VPS410-II / VPS421 voltage probe | From any terminal to earth ground 1000 V CAT III / 600 V CAT IV Between any terminal 1000 V CAT III / 600 V CAT IV |
Working voltage between probe tip and probe reference lead | VPS410-II: 1000 V VPS421: 2000 V |