China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xtester-CFV106 Pirani and cold cathode ion composite gauge

Xtester-CFV106 Pirani and cold cathode ion composite gauge

2024-04-18 17:38:32  

Xtester-CFV106 Pirani and cold cathode ion composite gauge

  • Main Features :
  • Serial No. : Xtester2400773
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

Xtester-CFV106 Pirani and cold cathode composite ion gauge

Overview

CFV106 wide range vacuum gauge, coupled with Pirani resistance gauge and cold cathode ionization gauge, with a range coverage


1.0E5Pa -1.0E-5Pa. This vacuum gauge device has a small volume, rich functions, and supports multiple display methods and data communication


The communication method has the advantages of simple use, easy installation, long service life, and less maintenance.

Features

1,Wide range, can hold up to 1.0E-8Torr ultra high vacuum degree detection
2,Using local display and real-time reading of vacuum degree values
3,Special electrode materials with low maintenance frequency and long service life
4,Dynamic compensation for holding temperature, eliminating the interference of environmental temperature fluctuations on measurement
5,Dual gauge interlocking, vacuum gauge can be safely started at any vacuum degree
6,Holding three display units: Pa, Torr, and mbar
7,Dual communication mode, simultaneously supporting analog and data communication (Modbus)
8,Wireless data transmission (optional, notstandard configuration)
9,Dual switch output
10,Set point power failure memory function
11,Adapted to IVMS data collection system, supporting data collection and storage

图片关键词

Technical Parameters

Measure Range1.0×10-5~1.0×10+5Pa (correction factor required for air, N2, other gases)
Accuracy

1.0×10-5~1.0×10-4Pa : ±20% 

1.0×10-4~1.0×10-2Pa : ±10%

1.0×10-2~1.0×10+4Pa : ±15% 

1.0×10+4~1.0×10+5Pa : ±50%

Data Collection
Resolution of 1%, response time<100ms
Temperature CharacteristicOperating temperature 0 ° C~+45 ° C, storage temperature -40 ° C~+75 ° C
Probe baking temperature100°C Max (excluding electronic control unit)
Power supplyRecommended+24VDC (± 20%)/0.5A, suitable for+5VDC~30VDC
Maximum power consumption6.0W Max
Signal Output5-bit segment code display, data communication (Modbus protocol), analog voltage output, wireless transmission
Control unitDual path optocoupler isolation control collector switch
Vacuum InterfaceInterface: DN25 ISO-KF (other options), the maximum pressure of the chamber is 1.5 × 10+5Pa
Vacuum contact materialSS316L stainless steel, tungsten, molybdenum, 95 porcelain, nickel
Ionic cathode structureMagnetic inverted non filament cathode
Weight450g (including DN25 ISO-KF flange)

图片关键词

Telephone
Email
Map
QQ Chat