China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

MEWOI-CD760 cable fault locator,POWER CABLE FAULT PRELOCATOR,Cable fault rangefinder
MEWOI-CD760 cable fault locator,POWER CABLE FAULT PRELOCATOR,Cable fault rangefinder
MEWOI-CD760 cable fault locator,POWER CABLE FAULT PRELOCATOR,Cable fault rangefinder
MEWOI-CD760 cable fault locator,POWER CABLE FAULT PRELOCATOR,Cable fault rangefinder
MEWOI-CD760 cable fault locator,POWER CABLE FAULT PRELOCATOR,Cable fault rangefinder
MEWOI-CD760 cable fault locator,POWER CABLE FAULT PRELOCATOR,Cable fault rangefinder

MEWOI-CD760 cable fault locator,POWER CABLE FAULT PRELOCATOR,Cable fault rangefinder

2024-09-14 18:48:32  

MEWOI-CD760 cable fault locator,POWER CABLE FAULT PRELOCATOR,Cable fault rangefinder

  • Main Features :
  • Serial No. : Xtester2400845
Contact US For Quotation  Email:464560351@qq.com  Whatsapp&Wechat:+8618620373879

MEWOI-CD760 cable fault locator,POWER CABLE FAULT PRELOCATOR,Cable fault rangefinder

Overview

The CD-760 Power Cable Fault locator is an easy operation device used for distance locating . It ’ s easy to operate,support both touch screen/button operation and with friendly interface.

Low voltage pulse mode (TDR ) can be used independently; In impulse current mode (ICM), it needs to be used with CD-6XX series high voltage signal generator; In the multiple impulse mode(MIM) must also be tested with CD-7505 cable multiple impulse filter coordination; After the distance measurement is completed, the CD-8XX series digital multifunctional cable fault pin-pointer shall be used for accurate point pinpointing. Together, they form a high-performance cable fault finding system that offers a variety of innovative features.

Features

Multiple distance locating method:

1,Low current impulse method: apply to the locating of the low resistance fault. Short circuit fault, open circuit fault. It also can be used in the measurement of the cable length, the intermediate joints, T joints, and cable termination joint. This method also can be used to correct the wave velocity.

2,Impulse current method: apply to the high resistance fault, breakdown fault. Use the current coupler to gather signal from the earth wire

3,Multiple impulse method: improvement of the SIM method.Waveform is clear and easy to identify, high ranging accuracy.

400MHz real-time sampling

1,Advance tech.Upgrading for SIM method

2,Max. 0.1m measurement resolution,CD-760 has small blind zone and is special for the short cable and nearly-terminal fault cable

Auto measurement function

1,Automatic selection of appropriate range and gain, given fault location, easier testing.

2,Only low voltage pulse mode supports this mode.

Automatic calibration function

1,Automatically analyze the characteristic waveform of the fault waveform and display the possible fault location .

2,Only low voltage pulse mode (TDR) supports this mode.

Enhance the picture-in-picture temporary comparison function

1,PIP copy ( pic. temporary storage). There'll be a main window and three temporary storage windows could check three waveform at same time.

2,Support low-voltage pulse and pulse current waveform comparison function, fault distance multi-direction verification, more accurate judgment.

Overall display function

1,When the waveform zoom, the overall waveform is displayed at the same time, which is more convenient for calibration and ranging.

Touch screen and press key operation

1,Touch operating screen with smart gesture operation

2,Support cursor drag-drop function and double-click function,easy to locate

Big color LED screen, friendly interface

1,Waveform clear, especially in the multiple impulse test,multiple waveform using different colors, easier to identify

2, 8" LED screen,bright with 1500cd/m2 to view under sunshine

3,Support automatic backlight brightness adjustment function

Waveform storage and PC communication

1,A large number of waveforms can be stored in the machine

2,Use USB disk to export waveform data

3,Waveform storage and communication with computer.

4,Provide computer background management software to manage data dumped by U disk or online data.

Power management

1,Back light weakens if no operation in 1 min and power off in 30 min. if no operation.

2,When the battery is under voltage, the instrument will automatically shut down to protect the battery.

3,Built-in Polymer Lithium-ion battery.

4,Working time could reach 10 hours for each use.

Solid case, light and portable.

Technical Specification

1,Working mode: low voltage pulse(TDR), pulse current(ICM), multiple pulse(MIM).

2,Signal gain adjustment range: 70dB.

3,Low voltage pulse emission voltage: 30V.

4,Measurement error: ± (0.5%×L+ 1M),L≥20m

5,Low pressure pulse pulse width: 40ns~ 20.5us

6,Highest resolution: 0.1m.

7,Maximum sampling frequency: 400MHz real-time sampling.

8,Maximum ranging range: 100km.

9,Wave speed setting range: 100m/ US ~300m/us

10,Ranging blind area: 2M.

11,Number of waveform saved: 100 pcs

12,Communication interface: USB, Bluetooth (optional)

13,Power supply: lithium-ion battery pack, nominal voltage 7.4V,6000mAh.

14,Battery power supply time: Use a fully charged polymer lithium ion battery, can last for more than 10 hours (with the battery aging, continuous service time will be reduced).

15,Charger: input AC220V, 50Hz, charging current 2A, charging time 6 hours.

16,Volume: 274×218×81mm

17,Quality: host unit 2.6kg

18,Conditions of use

19,Temperature: -10℃ ~ +40℃

20,Humidity: 5% ~ 90% RH (25℃)

Cable Fault Testing System

(Configuration Table for Power Cable Fault Testing System)


Items
Product Name/Model No.

Functions

图片关键词

MEWOI-CD650 Integrated High Voltage Signal Generator(necessity)

Generate high-voltage breakdown fault point

(Provide signal source for pulse current ranging, multiple pulse ranging, and precise fault location)

图片关键词MEWOI-CD760 POWER CABLE FAULT PRELOCATOR(Cable fault rangefinder)(necessity)

Measure the distance of the fault

Low voltage pulse, pulse current, multiple pulses, remote service (optional function)

图片关键词MEWOI-CD-850N Digital Cable Fault pin-pointer(necessity)

Determine the precise location of the fault point

(Waveform display method, intelligent method directly provide sound and magnetic delay values, strong noise reduction, adaptive noise reduction, no noise reduction, path compass display, automatic mute)

图片关键词

MEWOI-PD4950 Intelligent Pipe Locator,Cable routing and identification device (Optional)

Path detection, cable identification, real-time depth measurement, intelligent fault detection, pipeline survey

图片关键词MEWOI-CD-7505 Cable fault multi-impulse coupler (Optional)

Multiple pulse method for measuring fault distance


Scope of application

Detecting various types of faults such as low resistance, high resistance, flashover, disconnection, grounding, etc. in the main insulation of 35KV, 10KV, 380V and other bundled cables