Contact Us For Quotation | Email: 464560351@qq.com | Whatsapp&Wechat:+8618620373879 |
Xtester-LSH10-1A handheld ultrasonic Doppler current meter
Product introduction
LSH10-1A handheld ultrasonic Doppler current meter is a portable design, portable and easy to operate flow measuring instrument. It can be suspended, inserted and fixed for measurement. It can be widely used for flow velocity and flow measurement in hydrology, water conservancy, open channel, water supply and drainage, etc. |
Performance characteristics
1. High measurement accuracy, wide range, can measure weak current and strong current; 2. Sensitive sensing, high resolution, not limited by the starting flow rate; 3. Fast response speed, can measure instantaneous flow rate and average flow rate; 4. The measurement is linear and there are no K and C values of the calibration curve; 5. There are no mechanical rotating parts, and there are no problems such as sediment blockage or entanglement of water grass and sundries. It is most suitable for measurement in rivers with high content of suspended sediment, many floating objects such as water grass and extremely harsh ice age. |
Function introduction
1. Mini handheld host is convenient for users to carry and measure; 2. Large screen LCD display has continuous background light function; 3. Built in complete clock, convenient for users to calibrate and query time; 4. Equipped with data reading software to realize data storage, printing and output functions; 5. Real time display of instantaneous flow rate, average flow rate, instantaneous flow rate, average flow rate and water temperature; 6. The measurement mode is divided into automatic measurement and manual measurement to meet the needs of different occasions. |
Technical parameter
Measuring range | 0.02-7.00m/s |
Accuracy of flow measurement | 1.0%±1cm/s |
Resolving power | 1mm |
Water temperature measurement range | 0-40℃ |
Temperature measurement accuracy | ±1℃ |
Working water depth | 0.1-20m |
Measurement mode | Automatic and manual |
Measurement interval | Automatic mode: select the value in 0-120 minutes, with 5 minutes as the minimum increment or decrement interval unit |
Manual mode: single or multiple contact measurements can be made at any interval | |
Canal width | 0.5-10M |
Flow measurement range | Up to 9999m3 / h depending on the section shape |
Speed measurement duration | Automatic mode: 60 seconds and 100 seconds |
Manual mode: 10-120 seconds, increment or decrement selection | |
Working power supply | DC12V ± 10%, built-in lithium battery, full and continuous measurement > 200 times |
Output interface | RS485 or RS232 or USB interface, standard Modbus Protocol |
Power waste | Standby < 0.2W, speed measurement < 7W |
Volume and weight | Probe size: 390x140x140mm, weight: 2.5kg |
Host size: 209x110x40mm, weight: 0.5kg | |
Suitcase | Overall dimension: 580x330x180mm |
Measurement method | 1. Suspension measurement 2. Measurement of inserting rod 3. Measurement of fixed installation |
Weight size
Overall volume and weight Probe size: 390x140x140mm, weight: 2.5kg Host size: 209x110x40mm, weight: 0.5kg Outer packing box size: 595x195x355mm |
Ancillary functions
Flow = flow rate X cross-sectional area (rectangular, trapezoidal, triangular, circular) |