The SF6 gas leak detector is a precision instrument specifically designed to detect sulfur hexafluoride (SF6) gas leaks, widely used in fields such as power systems, industrial equipment, and environmental monitoring. SF6 gas is commonly used in power equipment such as high-voltage switches, GIS (gas insulated switchgear), transformers, etc. due to its excellent insulation and arc extinguishing performance. However, its leakage can have serious impacts on equipment safety, personnel health, and the environment (SF6's greenhouse effect potential is 23900 times that of CO2). The function of a leak detector is to quickly locate the leakage point and quantify the leakage concentration, ensuring reliable operation of the equipment and meeting environmental requirements. |
Features
1,It has full self checking functions such as low battery, sensor failure, and exceeding the range during the detection process; |
2,It has full self checking functions such as low battery, sensor failure, and exceeding the range during the detection process; |
3,Adopting color touch screen display and fully Chinese menu style function management; |
4,Real time display of detection data during the detection process; |
5,Large capacity rechargeable lithium battery with a continuous working time of more than 8 hours; |
6,Clock perpetual calendar function; |
7,Compact size, easy to hold for measurement; |
8,It has the function of storing 1000 pieces of data and the ability to browse and query; |
Technical Parameters
1 Display mode | 7-inch touch screen |
2 measurement methods: | NDIR single beam dual wavelength infrared measurement technology |
3 Monitoring gas, range, resolution, accuracy | Sulfur hexafluoride gas 0-2000ppm (0-5000ppm) (0-12000ppm) 1ppm ± (1.5%+5d) |
4 Repetitive Performance | 1% |
5. Pump extraction speed | ≥ 400ml/min |
6. The continuous working time | The continuous working time shall not be less than 7 hours |
7 Instrument start-up preheating time | ≤ 10 seconds |
8. Response time | less than 3 seconds |
9.Recovery time | less than 3 seconds |
10 charging adapter | DC12V/1A |
11 Surge (impact) immunity | ± 1.2kV |
12. Environmental temperature | -20 ℃ to+50 ℃ |
13 Environmental humidity | Relative humidity 5-95% (no condensation) |
14 Atmospheric pressure | 50kPa~110kPa |
15 protection level | IP33, double insulation, CAT II standard |
16 Dimensions: | Length 250mm, Width 160mm, Height 70mm |
17 host weight | 0.6kg |