China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xtester-Manual Digital Hart 475 Field Communicator for Transmitter Calibration
Xtester-Manual Digital Hart 475 Field Communicator for Transmitter Calibration
Xtester-Manual Digital Hart 475 Field Communicator for Transmitter Calibration
Xtester-Manual Digital Hart 475 Field Communicator for Transmitter Calibration
Xtester-Manual Digital Hart 475 Field Communicator for Transmitter Calibration
Xtester-Manual Digital Hart 475 Field Communicator for Transmitter Calibration

Xtester-Manual Digital Hart 475 Field Communicator for Transmitter Calibration

2024-05-06 11:42:08  

Xtester-Manual Digital Hart 475 Field Communicator for Transmitter Calibration

  • Main Features :
  • Serial No. : Xtester2400819
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

Xtester-Manual Digital Hart 475 Field Communicator for Transmitter Calibration

Overview

Xtester-Hart475 is the upgraded version based on Hart375. Ita hand held interface based on HART protocol,which could perform configuration, management, maintenance and adjustment to all HARTcompatible instruments. It can monitor input/ output value and self diagnosis results, set constant current output and zero adjustment. When the system starts or maintenance operation, as long as the HART communicator connected to 4~20mA communication signal line, you can use.


The device is suitable to the HART communication operation, compatible with hart275 hart375 and HART475. Can communicate1151,3051, EJA, abb and other HART protocol imported instruments, completely compatible with domestic intelligent pressure transmitter (temperature). Also communication operation with electromagnetic flowmeter, V cone flowmeter, target type flowmeter, vortex flowmeter, and others flowmeter supporting Hart protocal .

Features

 1,During the online monitoring and communication, modulation signal will not interrupt 4~20mA DC signal
2,Can work with the devices that adopt HART protocal   
3,Self diagnosis / protection function
4,Full function communication: flow meter, temperature meter, transmitter communication support carrying HART protocol
5,Large screen display, imported LCD screen
6,Can carry out inspection and production test of HART intelligent equipment etc.
7,HART intelligent equipment, in field operation, configuration, calibration, diagnosis, maintenance and monitoring etc.
8,Obtain field HART instrument manufacturers
9,Get the working state and fault information of HART instrument
10,Read the output current and the process variable
11,Get the parameters and output the value of the sensor
12,Self checking function
13,Formatted password protection
14,Low voltage alarm display
15,Standard technical specification

Specification

Product name

 Hart 475 field communicator

Function  

debugging Hart instruments

Color

black-white

Display

LCD

Weight

2.0kg as well as package

Size

30*22*10cm as well as package

Power supply

4.8V battery pack or 3pcs 1.5V dry battery

Type

handhold

Warranty

12 months after shippment

Functions

1,Set, change and display various parameters, HART communication
2,Constant current output
3,Zero adjustment function
4,Enter the password to protect formatting formatting
5,The battery alarm, LCD alarm information indicates the battery voltage is low
6,LCD contrast adjustment
7,Storage conditions: -15~55 degrees Celsius
8,Ambient temperature: 0~50 degrees Celsius

Packing List

1,Hart Field Communicator *1    
2,Battery *1    
3,Carrying case *1    
4,Charger *1    
5,Communication cable *1    
6,Operation Manual*1    
7,250ohm resistor *1

图片关键词

Telephone
Email
Map
QQ Chat