China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xester-HFT-C2H6O+HFM-301(1 channel gas controller+Fixed ethanol gas leak detector)alcohole detector ethanol leak detector
Xester-HFT-C2H6O+HFM-301(1 channel gas controller+Fixed ethanol gas leak detector)alcohole detector ethanol leak detector
Xester-HFT-C2H6O+HFM-301(1 channel gas controller+Fixed ethanol gas leak detector)alcohole detector ethanol leak detector
Xester-HFT-C2H6O+HFM-301(1 channel gas controller+Fixed ethanol gas leak detector)alcohole detector ethanol leak detector

Xester-HFT-C2H6O+HFM-301(1 channel gas controller+Fixed ethanol gas leak detector)alcohole detector ethanol leak detector

2024-07-20 09:46:19  

HFT-C2H6O+HFM-301(1 channel gas controller+Fixed ethanol gas leak detector)alcohole detector ethanol leak detector

  • Main Features :
  • Serial No. : Zoe114
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

Xester-HFT-C2H6O+HFM-301(1 channel gas controller+Fixed ethanol gas leak detector)alcohole detector ethanol leak detector


Single and Double Alarm Controller  Technical parameters of the system

1. Detection Principle: The system provides 24V standard DC voltage to external transmitter, collects input signal of standard 4-20mA transmitter, and performs digital display and alarm operation through analysis and processing.

2. Applicable object: The system supports input signals of standard transmitters. Such as gas transmitter: carbon monoxide, hydrogen sulfide, hydrogen, sulfur dioxide, ammonia, oxygen, chlorine and combustible gas and other gas transmitters. Table 1 is the setting table of the above gas technical parameters (for reference only, users can set parameters according to specific conditions). 

Molecular formula

Name of gas

Technical Indicators

measuring range

Resolution

Alarm Point

CO

Carbon monoxide

0-1000ppm

1ppm

50ppm

H2S

Hydrogen sulfide

0-200ppm

1ppm

10ppm

H2

hydrogen

0-1000ppm

1ppm

35ppm

SO2

sulfur dioxide

0-100ppm

1ppm

5ppm

NH3

ammonia

0-200ppm

1ppm

35ppm

NO

nitric oxide

0-250ppm

1ppm

25ppm

NO2

Nitrogen dioxide

0-20ppm

1ppm

5ppm

CL2

Chlorine

0-20ppm

1ppm

2ppm

O3

ozone

0-50ppm

1ppm

5ppm

O2

oxygen

0-30%vol

0.1%vol

Low 18%vol

High 23%vol

Ex

Combustible gas

0-100%LEL

1%LEL

25%LEL

CO2

Carbon dioxide

0-5%vol

0.01%vol

0.20%vol

 Transmitter Instruction Technical Parameters

Sensor: Electrochemical or Catalytic or Infrared Sensor

Responding time: ≤40s

Work pattern: Continuous operation

Working power supply: DC24V

Output Current: 4-20mA(or direct output relay switch)

Output: Two-wire or three-wire system(combustible gas only two-wire system)

Temperature range: -20℃ ~ 50℃

Humidity range: 10 ~ 90%(RH)No condensation

Ex-Proof: Exd II CT6

Installing mode: Wall or pipeline mounted installing(Note:Refer to the installation drawing)

Shape structure: Transmitter shell adopts flame-proof structure design of the die-casting aluminum shell, the groove design on the top cover is beneficial to lock shell, the front of the sensor adopts down design, this design guarantee the best contact between sensor and gas, its inlet wires are explosion-proof waterproof connectors .

Outline dimension:150mm×190mm×75mm

Weight:≤1.5kg

 



Telephone
Email
Map
QQ Chat