Product Introduction
Xtester-F200S-D Characteristics: |
Product Parameters
Mode:Xtester-F200S-D | Working distance: 5-200m |
Focused spot size : ≤15mm | Green pointer: 20~30mW |
Continuous working time:≥110 minutes | Cooling: Air-cooled |
Wavelength : 1080±5nm | Laser power: 200W adjustable |
Focus mode:Dynamic focus | Setting time: ≤2mins |
Power supply mode: external power source, lithium battery | Positioning: Auto-positioning, ≤30s |
Electronic telescope: 0-30 x optical zoom;1-10 x digital zoom | Protection mode: Dumping protection, foreign object detection, remote control |
Video recording and camera function: Two-way module | Night vision: Equipped |
Fault analysis and troubleshooting
Pressing the start button, the device does not start Check if the mergency stop switch is turned on, if the key switch is turned on, if the base of the platform touches the limit, and whether the platform and the laser are in standby state. The laser does not fire and screen shows“ Abnormal temperature” It is caused by temperature of the laser exceeding the allowable range, the laser shuts down automatically. Restart after several minutes of shutdown. If the alarm is still on, please check if the main cabinet cooling fan is blocked or not activated. The laser does not fire, but the power display is normal Check the indicator lights on both sides of the power display screen. When the laser light ( the red one at right side) is on and the power indicator ( left side) is off, it indicates that the laser starts protection state because the laser temperature is too high. Turn it off for a few minutes and then turn it back on. The machine is on, and then turn on the laser once the heat of the laser is appropriately decreased. Platform doesn’t response when press the button on keyboard Check if the equipment is on, if the antenna is well plugged in, if the power switch of the remote control is on, and whether the remote control battery is dead. No display on the remote control screen Check if the remote control switch is on, whether the data line is plugged in or loosened, if the SD card is plugged in, and if the remote control battery is dead. How to clean the equipment In order to ensure system works normally, it is necessary to carry out daily cleaning and maintenance of the equipment. This machine is a precision equipment, which requires extra care in maintenance. After each usage, clean it with powder-free rubber gloves, velvet-free cleaning cloth and cotton swabs, pure ethanol, alcohol (optical grade, purity greater than 99.5%), compressed air (oil-free, water-free) and other tools. Place the laser aiming head back into the main cabinet after wiping off the shell of it, the platform, display and so on. Please refer to the product instructions for details. |