China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xtester- CWDZ61 Hygienic Temperature Transmitter  316L to meet the hygiene requirements
Xtester- CWDZ61 Hygienic Temperature Transmitter  316L to meet the hygiene requirements
Xtester- CWDZ61 Hygienic Temperature Transmitter  316L to meet the hygiene requirements
Xtester- CWDZ61 Hygienic Temperature Transmitter  316L to meet the hygiene requirements
Xtester- CWDZ61 Hygienic Temperature Transmitter  316L to meet the hygiene requirements
Xtester- CWDZ61 Hygienic Temperature Transmitter  316L to meet the hygiene requirements

Xtester- CWDZ61 Hygienic Temperature Transmitter 316L to meet the hygiene requirements

2024-09-02 16:10:00  

CWDZ61 Hygienic Temperature Transmitter 316L to meet the hygiene requirements

  • Main Features :
  • Serial No. : Zoe347

Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

Xtester- CWDZ61 Hygienic Temperature Transmitter  316L to meet the hygiene requirements

 

CWDZ61 hygienic temperature transmitter for hygienic applications. The whole material is 316L to meet the hygiene requirements. Laser welding leveling process with protection up to IP69K (washable). The surface in contact with the process medium adopts plasma polishing process, so that it has the characteristics of easy cleaning and corrosion resistance. In addition, it is equipped with a variety of sanitary process connections to easily match different working conditions.

 

Technical parameters

Range: -50~150°C Output: 4~20mA, PT100 (1/3B class) Power supply: 9~36VDC Accuracy: 0.25%FS, 0.5%FS

 

[In addition, we can provide customized products to meet the needs of customers in a short period of time, according to their application.] ]

 

Typical applications

Medical technology, pharmaceutical industry, food and beverage industry

 

Measuring medium

Liquids, gases

 

Technical parameters

Basic parameters


Measuring medium

Liquid or gas, etc. (compatible with contact material)

Measuring range

-50~150℃

output signal

4~20mA, Pt100 (1/3B grade)

powered by

9~36VDC

Accuracy

0.25%FS, 0.5%FS

Resolution

Analog output 0.02%FS

Measuring element

1*Pt100(1/3B grade)

Response time

≈18s (compliant with IEC60751, 0.4m/s water flow, 10°C step)

Stable performance

±0.1%FS/year

Between

400ms

Maximum power

≤0.02Us(W) Note: Us=supply voltage

Load characteristics

Current type: load ≤{(Us-9)/0.02(Us=supply voltage)}Ω

Protection level

IP69K Note: The above protection level refers to the level achieved after the electrical connection is complete, and also depends on the electrical connection plug.

Ambient temperature

-40~85℃

environment humidity

0%~95%RH (no condensation and no condensation)

Electrical protection


Short circuit protection

permanent

Reverse polarity protection

No damage, but not working

Insulation resistance

≥100MΩ,500VDC

Dielectric strength

500VAC

Output Limitation


Output minimum

4mA

Output Max

20mA

Overall material


Protective tube

316 stainless steel (contacting the measured medium)

Process connection

316 stainless steel (contacting the measured medium)

shell

316L Stainless Steel

Mechanical stability


Vibration resistance

10g (20…2000Hz) in accordance with IEC60068-2-6 standard

Impact resistance

500g/ms in accordance with IEC60068-2-27 standard

  1.png 2.png


Telephone
Email
Map
QQ Chat