Xtester- CWDZ61 Hygienic Temperature Transmitter 316L to meet the hygiene requirements
CWDZ61 hygienic temperature transmitter for hygienic applications. The whole material is 316L to meet the hygiene requirements. Laser welding leveling process with protection up to IP69K (washable). The surface in contact with the process medium adopts plasma polishing process, so that it has the characteristics of easy cleaning and corrosion resistance. In addition, it is equipped with a variety of sanitary process connections to easily match different working conditions.
Technical parameters Range: -50~150°C Output: 4~20mA, PT100 (1/3B class) Power supply: 9~36VDC Accuracy: 0.25%FS, 0.5%FS
[In addition, we can provide customized products to meet the needs of customers in a short period of time, according to their application.] ]
Typical applications Medical technology, pharmaceutical industry, food and beverage industry
Measuring medium Liquids, gases |
Technical parameters
Basic parameters | |
Measuring medium | Liquid or gas, etc. (compatible with contact material) |
Measuring range | -50~150℃ |
output signal | 4~20mA, Pt100 (1/3B grade) |
powered by | 9~36VDC |
Accuracy | 0.25%FS, 0.5%FS |
Resolution | Analog output 0.02%FS |
Measuring element | 1*Pt100(1/3B grade) |
Response time | ≈18s (compliant with IEC60751, 0.4m/s water flow, 10°C step) |
Stable performance | ±0.1%FS/year |
Between | 400ms |
Maximum power | ≤0.02Us(W) Note: Us=supply voltage |
Load characteristics | Current type: load ≤{(Us-9)/0.02(Us=supply voltage)}Ω |
Protection level | IP69K Note: The above protection level refers to the level achieved after the electrical connection is complete, and also depends on the electrical connection plug. |
Ambient temperature | -40~85℃ |
environment humidity | 0%~95%RH (no condensation and no condensation) |
Electrical protection | |
Short circuit protection | permanent |
Reverse polarity protection | No damage, but not working |
Insulation resistance | ≥100MΩ,500VDC |
Dielectric strength | 500VAC |
Output Limitation | |
Output minimum | 4mA |
Output Max | 20mA |
Overall material | |
Protective tube | 316 stainless steel (contacting the measured medium) |
Process connection | 316 stainless steel (contacting the measured medium) |
shell | 316L Stainless Steel |
Mechanical stability | |
Vibration resistance | 10g (20…2000Hz) in accordance with IEC60068-2-6 standard |
Impact resistance | 500g/ms in accordance with IEC60068-2-27 standard |