Contact Us for Quotation | Email:464560351@qq.com | Whatsapp: +8618620373879 |
INTRODUCTION
Xtester110L Split Type High Accuracy Leakage Current Sensor is used for measurement of high accuracy AC current, leakage current, high order harmonic current, phase, power energy, power, power factor. Adopt the latest CT technology, double shielding layer and split type design, no need to disconnect the measured circuits, non-contact, safe and fast. It can be connected with phase detection analyzer, industrial control equipment, data recorder, oscilloscope, harmonic analyzer, electric power quality analyzer, high precision digital multi-meter, etc. Widely applied in electricity, communication, meteorology, railway, oilfield, construction, measurement, scientific and research teaching unit, industrial and mining enterprises.Xtester110L Split Type High Accuracy Leakage Current Sensor’ core is made of special alloy, adopt the newest magnetic shielding techniques, can almost shield the influence from external magnetic field, to ensure the high precision, high stability and high reliability of perennial uninterrupted measurement. |
TECHNICAL SPECIFICATION
Function | Measurement of AC current, leakage current, high order harmonic current, phase, power energy, power, power factor |
Test mode | Split Type CT |
Clamp Size | Φ10mm(available for line ≤10mm) |
Range | 0-60A AC |
Resolution | 1uA AC |
Accuracy | ±1.0%FS(50/60Hz; 23℃±2℃,below 70%RH, keep the wire be in the center of hole) |
Coils Turn | 800:1(customize is available) |
Phase Error | ≤2°(50Hz/60Hz; 23℃±2℃) |
Reference Load | RL: 0-600mA≤300ohm; 0-6A≤30ohm; 0-60A≤3ohm; |
Shielding | With shielding layer, apply to complicated environment with interference |
Output Interface | Current induction output |
Output Mode | 3.5mm audio plug(tail plug, banana pin, or BNC pin) |
Output Wire Length | 2m |
Electric Field Interference | About 5mA when the external electric field 100A, 10mm nearby |
Measured Wire Position | Approximately in the geometric center of the hole |
Current Frequency | 45H-60Hz(when measuring big current) |
Frequency | 10Hz-100kHz |
Voltage of circuit | AC 600V |
Dimension | 53mm×42mm×28mm |
Weight | 125g |
Working Environment | -20℃-50℃; below 80%rh |
Storage Environment | -10℃-60℃; below 70%rh |
Insulation Strength | AC 2kV/rms. (between core and shell) |
Safety Rules | IEC1010-1, IEC1010-2-032, Pollution degree 2, CAT Ⅲ(600V) |
Accessory | Sensor :1pc |
Split Type Current Sensor Probe
Click "Blue" marked Model No. to view the Spec
Model No. | Range | Clamp Size | Resolution | Coils Turn | Current induction output,Direct Coil tap | Double shielding, anti-jamming capability, suitable for leakage current, small current test |
Xtester110L | 0.000mA~ 60(AC) | Φ10mm | 1uA, Accuracy 1% | 1:800 | √ | √ |
Xtester110LE | 0.0mA~ 100mA(DC) | Φ10mm | 0.1mA, Accuracy 3% | 1:800 | √ | √ |
Xtester125L | 0.000mA~ 60(AC) | Φ25mm | 1uA, Accuracy 1% | 1:800 | √ | √ |
Xtester125LE | 0mA~ 100mA(DC) | Φ25mm | 1mA, Accuracy 3% | 1:800 | √ | √ |
Xtester140L | 0.00mA~ 200(AC) | Φ40 mm | 10uA, Accuracy 1% | 1:800 | √ | √ |
Xtester140LE | 0mA~ 100mA(DC) | Φ40 mm | 1mA, Accuracy 3% | 1:800 | √ | √ |
Xtester185L | 0.000mA~60A(AC) | 85*20mm | 1uA, Accuracy 1% | 1:800 | √ | √ |