China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xtester125LE Split Type High Accuracy Clamp Current Sensor Probe
Xtester125LE Split Type High Accuracy Clamp Current Sensor Probe
Xtester125LE Split Type High Accuracy Clamp Current Sensor Probe
Xtester125LE Split Type High Accuracy Clamp Current Sensor Probe

Xtester125LE Split Type High Accuracy Clamp Current Sensor Probe

2023-11-21 16:25:07  

Contact Us for QuotationEmail:464560351@qq.comWhatsapp: +8618620373879INTRODUCTIONXtester125LE Split Type DC Leakage Current Sensor is used for measurement of high accuracy DC leakage current, low DC

  • Main Features : Xtester125LE Split Type High Accuracy Clamp Current Sensor Probe
  • Serial No. :

Contact Us for QuotationEmail:464560351@qq.comWhatsapp: +8618620373879

INTRODUCTION

Xtester125LE Split Type DC Leakage Current Sensor is used for measurement of high accuracy DC leakage current, low DC current. Adopt the latest CT technology, double shielding layer and split type design, portable, install on line, no need to disconnect the measured circuits, non-contact, safe and fast. It can be connected with phase detection analyzer, industrial control equipment, data recorder, oscilloscope, harmonic analyzer, electric power quality analyzer, high precision digital multi-meter, etc. Widely applied in electricity, communication, meteorology, railway, oilfield, construction, measurement, scientific and research teaching unit, industrial and mining enterprises.

TECHNICAL SPECIFICATION

FunctionMeasurement of DC leakage current, low DC current
Test modeSplit Type CT
CT SizeΦ25mm(available for line $25mm)
Range0~100mA (DC)
Resolution0.1mA (DC)
Accuracy±3.0%FS(23℃±2℃, below 70%RH, keep the wire be in the center of clamp)
Coils Turn800:1
Power supply9VDC±1VDC
Power consumption20mA max
Signal output25mV/1mA(0~100mA output 0~2.5V)
Response speed2 times/sec
Output InterfaceBrown—positive power input; Yellow—terminal of alert control; Blue—anode signal output; black—GND(cathode power output and cathode signal output, can short circuit with shielding shell )
Output Wire Length2m(Customize is allowed)
Electric Field Interference3mA
Measured Wire PositionApproximately in the center of the closed core
Current Frequency45HZ-60Hz(when measuring big current)
Frequency Feature10Hz~100kHz
Voltage of circuitBelow DC 600V
Dimension78mmx64mmx31mm
WeightAbout 200g
Working Environment-10℃ ~ 45℃; below 80%rh
Storage Environment-10℃ ~60℃; below 70%rh
Insulation StrengthAC 2KV/rms.(between the core and shell)
Safety RulesIEC1010-1,IEC1010-2-032,Pollution degree:2 CAT Ⅲ(600V)
AccessoriesSensor 1 piece

SELECTION GUIDE

Split Type Current Sensor Probe

Click "Blue" marked Model No. to view the Spec


Model No.RangeClamp SizeResolutionCoils TurnCurrent induction output,Direct Coil tapDouble shielding, anti-jamming capability, suitable for leakage current, small current test
Xtester110LMEWOI110L.001.80.jpg0.000mA~ 60(AC)Φ10mm 1uA, Accuracy 1%1:800
Xtester110LEMEWOI110LE.80.jpg0.0mA~ 100mA(DC)Φ10mm 0.1mA, Accuracy 3%1:800
Xtester125LMEWOI125L.80.001.jpg0.000mA~ 60(AC)Φ25mm 1uA, Accuracy 1%1:800
Xtester125LEMEWOI125LE.80.001.jpg0mA~ 100mA(DC)Φ25mm 1mA, Accuracy 3% 1:800
Xtester140LMEWOI140L.80.jpg0.00mA~ 200(AC)Φ40 mm 10uA, Accuracy 1%1:800
Xtester140LEMEWOI140LE.80.002.jpg0mA~ 100mA(DC)Φ40 mm 1mA, Accuracy 3%1:800
Xtester185LMEWOI185L.80.jpg0.000mA~60A(AC)85*20mm 1uA, Accuracy 1%1:800


Telephone