China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xtester-DS5000LAA-(500A-5000A) (AC/DC) 102-38mm Open-loop Hall current Sensor

Xtester-DS5000LAA-(500A-5000A) (AC/DC) 102-38mm Open-loop Hall current Sensor

2022-11-24 15:03:50  

Electricity Testing Instruments manufacturer, Support OEM/ODM, your testing specialist

  • Main Features : Xtester-DS5000LAA-(500A-5000A) (AC/DC) 102-38mm Open-loop Hall current Sensor
  • Serial No. :
Contact Us for QuotationEmail:464560351@qq.comWhatsapp: +8618620373879

Xtester-DS5000LAA-500A-5000A (AC/DC) 102*38mm Open-loop Hall current Sensor

The current sensor basedXtester- on the Hall Effect open-loop principle can measure DC, AC, pulse and various kinds of Irregular waveform current under electrical isolation conditions.

TECHNICIAL SPECIFICATION

Click to download: Xtester-DS5000LAA-(500A-5000A (AC/DC) 102*38mm Open-loop Hall current Sensor  

Model Number

              Xtester-DS5000LAA-(600A-5000A) (AC/DC)

Jaw Size

102*38mm

Rated input Current (IPN)

500

1000

2000

3000

5000

A

Primary Current Measure range(IP)

0~±1000

0~±2000

0~±4000

0~±6000

0~±6000

A

Rated output voltage of secondary side

4±1%

V

Power Supply Voltage (VCC)

±12-±15(±5%)

V

Current consumption

VC=±15V                    <30

mA

Galvanic isolation (Vd)

6KV /50Hz/1min


Linearity (εL)

<1

%FS

Accuracy X

TA =25℃                                  ±1

%

Offset Voltage V0

TA=25℃                      <±25 

mV

Hysteresis offset Current IOM

IPN→0                        <±20

mV

Offset Voltage drift VOT

IP=0  TA=-25~+85℃                <±1

mV /℃

Response time Tr

<7

μs

Operating temperature TA

-25~+85

Storage temperature TS

-40~+100

Frequency bandwidth(-3dB)

DC-20

KHZ

Load resistance RL

≥10k

Ω

Weight

650

g

Matters needing attention:

  • The wrong connection may cause sensor damage. After the sensor is energized, the same phase voltage is measured at the output when the current wire cross the sensor center according the direction arrow indicating label.

  • The output range of the sensor can be adjusted according to the user's needs.

  • Vout is positive when the Ip flows in the direction of the arrow.

Hall Current Sensor  Selection Guide

Model NumberRangeDiameterOutputPower Supply

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester-DRB1

50,100,200,300A20mm(Close Loop)50,100,100,150mADC ±12V~±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester-DRK1D

50,100,200,300,400,500A(AC/DC)21mm(Open Loop)2.5±1.25V  ( ±1%)DC  +5V (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester-DRK1

50,100,200,300,400,500A(AC/DC)21mm(Open Loop)4or5,4-20 mA,0-20 mA±1%DC ±12V~±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester-DRK1AC

50,100,200,300,400,500A(AC)21mm(Open Loop)4or5,4-20 mA,0-20 mA±1%DC ±12V~±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester-DRK3D

50,100,200,300,400,500A(AC/DC)10*20mm(Open Loop)2.5V±1.25V    ±1%DC  +5V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester-DRK3

50,100,200,300,400,500A(AC/DC)10*20mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester- DRK5

300,500,600,800,1000,1500A(AC/DC)37*42.5mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester- DRKH1

50,100,200,300,400,500A(AC/DC)21mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester- DRKH2

300,400,600,800,1000,2000A(AC/DC)40.5mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester- DRKH4

600,800,1000,2000,2500,3000A(AC/DC)80mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester- DRKH5

600,1000,2000,3000,5000A(AC/DC)42*400mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester-DS10000LC

1000,3000,5000,8000A,10000A(AC/DC)140*36mm(Open Loop)4±1%DC  ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester- DS8000DKL

10000,20000,30000,40000,60000A,80000A(AC/DC)120mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester- DS4000IAX

500,800,1000,1500,2500A,4000A(AC/DC)64*21mm(Open Loop)4±1%DC  ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester-MEWOI DS1500DFA

200,400,600,800,1000A,1500A(AC/DC)
40*30.2mm(Open Loop)
4±1%DC  ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS20000IC

5000,7500,10000,15000,20000A,(AC/DC)210*100mm(Close Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS10000IB

2000,3000,5000,8000,10000A,(AC/DC)140*50mm(Close Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS6000FKF

300,600,1000,2000,4000,6000A,(AC/DC)φ62mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS5000LA

600,1000,2000,3000,5000A,(AC/DC)104*36mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester-MEWOI DS5000LAA

500,1000,2000,3000,5000A,(AC/DC)102*38mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS2500LF2

500,1000,1500,2000,2500A,(AC/DC)85*27mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS2000L

300,500,800,1000,2000A,(AC/DC)64*16mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS2000GA

400,500,800,1000,2000A,(AC/DC)51*13mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS2000FB

500,800,1000,1500.2000A,(AC/DC)φ60.5mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS1000T

100,200,300,400,500,600,1000A,(AC/DC)φ32mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS1000FD

200,400,700,1000A,(AC/DC)φ17.5mm4±1%DC  ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS1000CF

200,400,600,800,1000A,(AC/DC)40.5*20.5mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS800FKH.80.jpg

Xtester- DS800FKH

100,200,300,500,800A,(AC/DC)φ35mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS600P.80.jpg

Xtester- DS600P

50,100,200,300,400,500,600A,(AC/DC)26*12mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI-DS600F2.80.jpg

Xtester- DS600F2

100,200,300,400,500,600A,(AC/DC)φ28mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS600C.80.jpg

Xtester- DS600C

50,100,200,300,400,500,600A,(AC/DC)20.5*10.2mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS400FKC.80.jpg

Xtester- DS400FKC

50,100,150,200,300,400A,(AC/DC)φ12mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS040H.80.jpg

Xtester- DS040H

10,20,30,40A(AC/DC)φ5mm1±1%DC  ±12V- ±15V  (±5%)

MEWOI-DS2000DKO.80.jpg

Xtester-DS2000DKO

500,1000,5000,8000

12000,20000(AC/DC)

φ80mm4or5±1%DC  ±12V- ±15V  (±5%)



Telephone
Email
Map
QQ Chat