TECHNICIAL SPECIFICATION

Click to download:Xtester-DRB1-(50-300A) (AC/DC) φ20mm Closed-loop Hall current Sensor Specification

Model NumberXtester-DRB1-(50-300A)(AC/DC)
Diameter
φ20mm
Rated input Current (IPN)50100200300A(AC/DC)
Primary Current Measure range(IP)0~±750~±1500~±3000~±350A
Rated output voltage of secondary side50100150150mA
Turn ratio Kn1:10001:10001:20001:2000
Measure resister range Rm0-2000-2000-800-80Ω
Power Supply Voltage (VCC)DC ±12V~±15V  (±5%)V
Current consumptionVCC=±15V      10+ ISmA
Galvanic isolation (Vd)2.5KV /50Hz/1minV
Linearity (εL)<0.1%FS
Accuracy XTA =25℃                                  ±0.7%
Offset Current I0TA =25℃                                  ±0.2mA
Hysteresis offset Current IOM<±0.3mA
Offset Voltage drift VOTIP=0  TA =-25~+85℃                      <±0.5mA
Response time Tr<1μs
Operating temperature TA-25~+85
Storage temperature TS-40~+100
Load resistance RL≥10KΩ
Matters needing attention:
  • The wrong connection may cause sensor damage. After the sensor is energized, the same phase voltage is measured at the output when the current wire cross the sensor center according the direction arrow indicating label.

  • The output range of the sensor can be adjusted according to the user's needs.

  • During the installation process, before closing the jaw, make sure the connecting interface is aligned, not forcibly closed

Hall Current Sensor  Selection Guide

Model NumberRangeDiameterOutputPower Supply

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester--DRB1

50,100,200,300A20mm(Close Loop)50,100,100,150mADC ±12V~±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester--DRK1D

50,100,200,300,400,500A(AC/DC)21mm(Open Loop)2.5±1.25V  ( ±1%)DC  +5V (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester--DRK1

50,100,200,300,400,500A(AC/DC)21mm(Open Loop)4or5,4-20 mA,0-20 mA±1%DC ±12V~±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester--DRK1AC

50,100,200,300,400,500A(AC)21mm(Open Loop)4or5,4-20 mA,0-20 mA±1%DC ±12V~±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester- DRK3D

50,100,200,300,400,500A(AC/DC)10*20mm(Open Loop)2.5V±1.25V    ±1%DC  +5V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester- DRK3

50,100,200,300,400,500A(AC/DC)10*20mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester- DRK5

300,500,600,800,1000,1500A(AC/DC)37*42.5mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester- DRKH1

50,100,200,300,400,500A(AC/DC)21mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester- DRKH2

300,400,600,800,1000,2000A(AC/DC)40.5mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester- DRKH4

600,800,1000,2000,2500,3000A(AC/DC)80mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester- DRKH5

600,1000,2000,3000,5000A(AC/DC)42*400mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester--DS10000LC

1000,3000,5000,8000A,10000A(AC/DC)140*36mm(Open Loop)4±1%DC  ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester- DS8000DKL

10000,20000,30000,40000,60000A,80000A(AC/DC)120mm(Open Loop)4or5±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe

Xtester- DS4000IAX

500,800,1000,1500,2500A,4000A(AC/DC)64*21mm(Open Loop)4±1%DC  ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS1500DFA

200,400,600,800,1000A,1500A(AC/DC)
40*30.2mm(Open Loop)
4±1%DC  ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS20000IC

5000,7500,10000,15000,20000A,(AC/DC)210*100mm(Close Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS10000IB

2000,3000,5000,8000,10000A,(AC/DC)140*50mm(Close Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS6000FKF

300,600,1000,2000,4000,6000A,(AC/DC)φ62mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS5000LA

600,1000,2000,3000,5000A,(AC/DC)104*36mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS5000LAA

500,1000,2000,3000,5000A,(AC/DC)102*38mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS2500LF2

500,1000,1500,2000,2500A,(AC/DC)85*27mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS2000L

300,500,800,1000,2000A,(AC/DC)64*16mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS2000GA

400,500,800,1000,2000A,(AC/DC)51*13mm(Open Loop)4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS2000FB

500,800,1000,1500.2000A,(AC/DC)φ60.5mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS1000T

100,200,300,400,500,600,1000A,(AC/DC)φ32mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS1000FD

200,400,700,1000A,(AC/DC)φ17.5mm4±1%DC  ±15V  (±5%)

MEWOI-clamp meter|earth ground resistance tester|pinza|curent sensor probe|power quality analyzer

Xtester- DS1000CF

200,400,600,800,1000A,(AC/DC)40.5*20.5mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS800FKH.80.jpg

Xtester- DS800FKH

100,200,300,500,800A,(AC/DC)φ35mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS600P.80.jpg

Xtester- DS600P

50,100,200,300,400,500,600A,(AC/DC)26*12mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI-DS600F2.80.jpg

Xtester- DS600F2

100,200,300,400,500,600A,(AC/DC)φ28mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS600C.80.jpg

Xtester- DS600C

50,100,200,300,400,500,600A,(AC/DC)20.5*10.2mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS400FKC.80.jpg

Xtester- DS400FKC

50,100,150,200,300,400A,(AC/DC)φ12mm4±1%DC  ±12V- ±15V  (±5%)

MEWOI DS040H.80.jpg

Xtester- DS040H

10,20,30,40A(AC/DC)φ5mm1±1%DC  ±12V- ±15V  (±5%)

MEWOI-DS2000DKO.80.jpg

Xtester-DS2000DKO

500,1000,5000,8000

12000,20000(AC/DC)

φ80mm4or5±1%DC  ±12V- ±15V  (±5%)


Telephone
Email
Map