Application
TM-6002 is an ideal tester for automotive, UPS maintenance and telecommunication applications. Quick response time. Simultaneously display the results of battery Impedance,voltage measurements. Built-in comparator function to rate the conditions as pass,warning or fail.
|
Features
The Battery Tester is designed for measuring the internal impedance and open circuit voltage of the secondary battery including Nickel-metal hydride battery ( NiMH),Nickel-cadmium battery(NiCd),Lithium-ion battery(Li-ion), Alkaline battery and lead-Acid battery. AC four-terminal method to measure the internal impedance by eliminating lead impedance and contact impedance to get the accurate results. Multi-display to show the internal impedance, voltage and clock of the battery simultaneously. It has 99 sets of composite comparator function, which can be set at impedance and voltage values to get the reliable detection of battery deterioration. Pin type leads, which can easily contact the battery electrodes supplied as standard to get more accurate 4-terminal measurement.
|
Specifications
Display:LCD display and LEDs (comparator output). Sampling rate:2 Second. Open-Circuit terminal voltage: 7.0Vp-p max. Input over range: the screen displays “OL”. Low battery detection: the screen displays “”. Autopower off: The meter will turn off automatically after about 15 minutesof inactivity, allows user to set the inactive time (01〜99 minutes). Comparator settings: High and Low limits of the comparators impedance and voltage. Number of comparator settings: 99 sets. Manual and auto continuous Data logging: 9999 sets. Dimension: 240mm(L)x100mm(W)x45mm(H). Weight:about 700g. (Including battery) Fuse specification: 0.5A/250V, 3.6Øx 10mm.
|
Electrical Specifications:(23℃±5℃, below 80%RH )
Resistance measurements |
•Temperature coefficient :±(0.1% rdg+0.5digits)/℃. •Measurement current frequency:1KHZ±30HZ. •Measurement open-circuit terminal voltage:7Vp-p |
Range | Resolution | Measurement current | Accuracy |
40mΩ | 10μΩ | 100m A approx. | ±(0.8%reading+10digits) |
400mΩ | 100μΩ | 15m A approx. |
4Ω | 1mΩ | 1.5m A approx. |
40Ω | 10mΩ | 150μm Aapprox. |
Voltage Measurements |
Temperature coefficient:(±0.1% rdg ±0.5digits)/°C |
Range | Resolution | Accuracy |
4V | 1mV | ±(0.1% reading+6digits) |
40V | 10mV |
Temperature measurement |
Measurement Range | Resolution | Accuracy |
-20°C~60°C -4°F~140°F | 0.1°C 0.1°F | ±1.0°C ±1.8°F |
DC Current (DCA) measurement (optional TM-1104) |
Range | Sensitivity | Resolution | Accuracy |
700A | 0.6A〜700.0A | 0.1A | ±(2.0% reading+5digits) |
Accessories
User’s Manual Kevin Clip type leads with temperature sensor Pin type leads AC100~240V 9V/1A(5.5*2.1*1.0mm) switching transformer 1.5 V – LR6 – AA – AM3 – MN 1500. Carrying Case 5-pin USB cable Installation CD
|