Contact Us For Quotation | Email: 464560351@qq.com | Whatsapp&Wechat:+8618620373879 |
Xtester-TM282D Ultrasonic Thickness Gaugethickness Testing Machinethickness Meter with A&B Scan
More Practical Function
Difference/Reduction Information displays: LOS, min, max, large reading while displaying min at the same time, velocity, zero, calibration, units, freeze, unfreeze, % battery life remaining, gain - low, std, high, echo to echo symbol Max./Min. Capture: On this mode, the current thickness, minimum thickness and the maximum thickness will be shown on the screen at the same time. Alarm Mode: Dynamic change the color of thickness readings when alarming. Update Rate: Selectable 4Hz, 8hz and 16Hz. 4Hz for ordinary application, when you need a quick scan, such as high temperature measurement, you can choose higher update frequency. Multi- Languages Available: Chinese,English, Spanish, German. Echo to Echo: Measures the metal thickness only (ignore paint and coatings) Data logger: 99999 thickness data logger with ID point in linear or grid files ( 400 files) Output: USB 2.0 full speed connector. DataView report software Size: 156mm) (L) 76mm) (W) x 1.25" (38 mm) (H) Weight: 285 g Temperature: Gage Operating:-10° C to 50° C |
The Difference Between TM281 Series Ultrasonic Thickness Gauge
TM282 | TM282D | |
Color Display | √ | √ |
Live A-Scan | √ | √ |
Time-based B-Scan | √ | √ |
Control of Gain and Gate | √ | √ |
Blanking | √ | √ |
Thru-paint&coatings | × | √ |
Data Logger | × | × |
DataView Software | × | × |
Specifications of TM282DL Ultrasonic Thickness Gauge
Display Type | 2.4'' color OLED, 320×240 pixels, display |
Operating Principle | Pulse echo with dual elemet |
Measuring Range | 0.50mm to 508mm(0.02'' to 20.00''), |
Measuring Resolution | Selectable 0.01mm, 0.1mm(selectable |
Units | Inch or Millimeter |
Rectify Mode | RF+, RF-, HALF+, HALF-, FULL |
Display Mode | Normal, Minimum/Maximum capture, |
V-Path Correction | Automatic |
Update Rate | Selectable 4Hz, 8Hz, 16Hz |
Material Velocity Range | 500 to 9999m/s(0.0197 to 0.3939 |
Languages | English, French, German,spanish,Chinese |
Alarm Settings | Minimum and Maximum alarms. Range of |
Power Requirements | 2 AA size batteries |
Operating Time | Approximately 40 hours |
Instrument Shut-off | Selectable ALWAYS ON or AUTO OFF |
Operating Temperature | -10℃ to +50℃(+10°F to +12°F ) |
Size | 158mm × 76mm × 37mm (H × W × D) |
Weight | 285g including batteries |
Standard Delivery TM282DL
Name | Quantity |
Main body | 1 |
Probe | 1 |
Battery | 1 |
Couplant | 1 |
Carrying Case | 1 |
Operating Manual | 1 |
USB Cable | 1 |
Software | 1 |