China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xtester-SKZ1053A laboratory automatic 1150C tga thermogravimetric analyzer
Xtester-SKZ1053A laboratory automatic 1150C tga thermogravimetric analyzer
Xtester-SKZ1053A laboratory automatic 1150C tga thermogravimetric analyzer
Xtester-SKZ1053A laboratory automatic 1150C tga thermogravimetric analyzer

Xtester-SKZ1053A laboratory automatic 1150C tga thermogravimetric analyzer

2024-07-29 14:38:38  

SKZ1053A laboratory automatic 1150C tga thermogravimetric analyzer

  • Main Features :
  • Serial No. : Zoe192

Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

Xtester-SKZ1053A laboratory automatic 1150C tga thermogravimetric analyzer

Thermo gravimetric analysis (TG, TGA) is to observe the change of sample quality with temperature or time in the process of heating and constant temperature, the purpose is to study the thermal stability and composition of the material.
Widely used in the research and development, process optimization and quality control of plastics, rubber, coatings,
pharmaceuticals, catalysts, inorganic materials, metal materials and composite materials


Application range:

Thermal stability, decomposing process, adsorption and desorption, oxidation and reduction, ingredients quantitative analysis,additives and filler influence, moisture and volatiles, reaction kinetics.


Structural advantages:

1.The furnace body is heated by double-row winding of precious metal nickel-cadmium alloy wire, which reduces interference and is more resistant to high temperatures.
2.The tray sensor is made of precious metal alloy wire, which has the advantages of high temperature resistance, oxidation resistance and corrosion resistance.
3.The power supply and circulating heat dissipation part are separated from the main machine to reduce the influence of heat and vibration on the micro-thermal balance.
4.Adopt top-opening structure, easy to operate. It is difficult to move the furnace body up to place the sample, and it is easy to damage the sample rod.
5.The host uses the heat insulation of the heating furnace body to the chassis and micro-thermal balance.
6.The furnace body can be replaced according to customer requirements.


Controller and software advantages:

1. Using imported ARM processor, sampling speed, processing speed is faster.
2. Four-channel sampling AD collects TG signal and temperature T signal.
3. Heating control, using PID algorithm, precise control. Multi-stage heating and constant temperature
4. The USB two-way communication is adopted between the software and the instrument to fully realize remote operation. The parameter setting of the instrument and the operation and stop of the instrument can be carried out through the computer software.
5. 7-inch full-color 24bit touch screen, better man-machine interface. TG calibration can be achieved on the touch screen


Specification

Temperature range

Actual maximum temperature 1150℃(SKZ1053A)
Actual maximum temperature 1350℃(SKZ1053B)
Actual maximum temperature 1600℃(SKZ1053C)

Temperature resolution

0.01℃

Temperature fluctuation

±0.01℃

Heating rate

0.1 ~ 100 ℃ / min

Temperature control mode

Rising, Constant temperature

Program control

Program setting multi-stage heating and constant temperature

Cooling time

15min (1000℃ ~ 100℃), Natural cooling

Balance measuring scope

1mg~3g , Can be expanded to 50g

Sensitivity

0.01mg

Constant temperature and time

0 ~ 300min (set arbitrarily)

Display

Liquid crystal display (LCD), English version

Atmosphere device

Built-in gas flow meter, includes switch two path gas and control flow volume

Software

Record TG curves automatically, Processing data and print

Data interface

USB interface

Power

AC220V 50Hz

Size

500*400*430mm

 

Product details

1.Provide different specifications of voltage, plugs according to customers’ needs.USB communication interface, strong versatility, reliable and uninterrupted communication, supports self-recovery connection function.

2.Automatically switch the two-channel atmosphere flow, fast switching speed and short stabilizat

4.Adopt top-opening structure, easy to operate. It is difficult to move the furnace body up to place the sample, and it is easy to damage the sample rod.

5.The heating part of the furnace body adopts double-row winding of high temperature wire, which reduces interference and is more resistant to high temperature.
The tray of the sensor is made of alloy wire, made with precision, anti-oxidation, high temperature resistance and corrosion resistance.

6.The furnace body can be replaced according to customer requirements.


s (1).pngs (2).pngs (3).pngs (4).pngFAQ WHATSAPP1691145100957_ 

 

 

 


Telephone
Email
Map
QQ Chat