Contact Us For Quotation | Email: 464560351@qq.com | Whatsapp&Wechat:+8618620373879 |
Xtester-SF126 Mini Touch Screen Commercial Drinks Cabinet Refrigeration Temperature Controller
Product descripyion
Mini-sized and integrated intelligent control, can control 1HP compressor directly. (Include 1HP) Temperature Display/ Temperature Control/ Manual, automatic defrost / Defrost by turning off compressor/High, low temperature alarm/Value Storing/ Self Testing |
Specifications
Power supply: 220V~240VAC Temperature sensor: NTC, one sensor(for cold room temp. control),2m(L) Range of temperature displayed : -45~99°C(-49~210℉) Accuracy: ±1℃(±2℉) Range of set temperature: E1~E2 Factory default : 0.0℃(32.0℉) Dimension:77(Length)*35(Width)*70(Depth)mm Mounting hole dimension:71(Length)*29(Width)mm Temperature of the operating environment: -10~60℃(14~140℉) Relative Humidity:20%~90%(Non-condensing) Output contact capacity: Compressor: N. O. 30A/250VAC (Can control 1HP compressor directly, if more it needs to connect an AC contactor) |
Parameters
Paramenter | Function | Set range | Default |
E1 | Lowerset point limit | -49℉ -45℃~set temp. | -31.0℉ -35.0℃ |
E2 | Higher set point limit | Set temp.~113℉ 45.0℃ | 68.0℉ 20.0℃ |
E3 | Temp. Hysteresis | 2.0~36.0℉ 1.0~20.0℃ | 7.0℉ 4.0℃ |
E4 | Comp. Start delay time | 00~10min | 2min |
E5 | Offset on room temp. | -36~36.0℉ -20~20.0℃ | 0.0℉ 0.0℃ |
F1 | Max. Defrost duration | 01~60min | 20min |
F2 | Defrost interval time | 00~24hr | 0hr |
F4 | Display during defrost | 00=normal display 01=last value befrost defrost 02=display dEF | 01 |
C1 | High temp. alarm | C2~113℉ 45.0℃ | 113℉ 45.0℃ |
C2 | Low temp. alarm | -49 -45℃~C1 | C1 |
C3 | Alarm hysteresis | 2.0~36.0℉ 1.0~20.0℃ | 4.0℉ 2.0℃ |
C4 | Alarm delay time | 00~90min | 30min |
CF | Temperature unit | ℃=Celsiu s ℉=Fahrenheit | ℃ |