a very high sensitivity model,X1,x10,x100 attenuation ratio can satisfied a wide range voltage measurement.It can be use with all oscilloscopes.

  • Main Features :
  • Serial No. :
Contact Us for QuotationEmail: mewoi008@mewoi.comWhatsapp:+8619928420370

Xtester-PT5800 (50MHz,800V) Differential probe-high sensitivity

INTRODUCTION

Suitable for large power, test R & D use; Using adapter power supply mode, BNC can be compatible with different brands of oscilloscopes, and the test accuracy is 2%.

A variety of voltage test models, can meet a variety of high voltage test needs.
Multiple attenuating switches make testing easier.

 Technical Specification

Model

Xtester-PT-5800

Bandwidth(-3dB)

DC-50MHz

Attenuation Ratio

x1,x10,x100

Rise time

7ns

Accuracy

±2%

Input AC Voltage(Vp-p)

800V

Input DC Voltage

400V

Input AC Voltage(AC rms)

280V

Between Impedance

3MΩ//2.5pF

Oscilloscope input impedance

1MΩ

Noise(In 50Ω load)

≤1mV rms

Size

218*83*30 mm

Selection Guide

ModelXtester-PT-5215Xtester-PT-5800Xtester-PT-5208Xtester-PT-5216
Bandwidth(-3dB)DC-35MHzDC-50MHzDC-50MHzDC-50MHz
Attenuation Ratiox100,x1000x1,x10,x100x10,x100,x1000x20,x200,x2000
Rise time10ns7ns7ns7ns
Accuracy±2%
Input AC Vp-p1.5kV@1/100 15kV@1/10008V@1/1 80V@1/10 800V@1/1008V@1/10 80V@1/100 8kV@1/1000160V@1/20 1.6kV@1/200 16V@1/2000
Input DC Voltage750V@1/100 7.5kV@1/10004V@1/1 40V@1/10 400V@1/10040V@1/10 400V@1/100 4kV@1/100080V@1/20 800V@1/200 8kV@1/2000
Input AC Voltage(AC rms)5.5kV280V2.8kV5.6kV
Between Impedance50MΩ/1.3pF3MΩ/2.5pF20MΩ/2pF30MΩ/1.5pF
Oscilloscope input impedance1MΩ
Noise In 50Ω load≤1mV rms≤1mV rms≤1mV rms≤2mV rms
Size220x85x30mm218x83x30mm218x83x30mm218x83x30mm
ModelXtester-PT-5160LXtester-PT-5160MXtester-PT-5160
Bandwidth(-3dB)DC-50MHzDC-70MHzDC-100MHz
Attenuation Ratiox100,x1000x100,x1000x100,x1000
Rise time7ns5ns3.5ns
Accuracy±2%
Input AC Vp-p1.6kV@1/100 16kV@1/10001.6kV@1/100 16kV@1/10001.6kV@1/100 16kV@1/1000
Input DC Voltage800V@1/100 8kV@1/1000800V@1/100 8kV@1/1000800V@1/100 8kV@1/1000
Input AC Voltage(AC rms)5.6kV5.6kV5.6kV
Between Impedance20MΩ/5pF20MΩ/5pF20MΩ/5pF
Oscilloscope input impedance1MΩ
Noise In 50Ω load≤1mV rms≤1mV rms≤1mV rms
Size220x85x30mm220x85x30mm218x83x30mm