China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xtester-ME231 Three-phase multifunctional smart meter,10A,100A,500A,1000A,3000A,6000A optional
Xtester-ME231 Three-phase multifunctional smart meter,10A,100A,500A,1000A,3000A,6000A optional
Xtester-ME231 Three-phase multifunctional smart meter,10A,100A,500A,1000A,3000A,6000A optional
Xtester-ME231 Three-phase multifunctional smart meter,10A,100A,500A,1000A,3000A,6000A optional
Xtester-ME231 Three-phase multifunctional smart meter,10A,100A,500A,1000A,3000A,6000A optional
Xtester-ME231 Three-phase multifunctional smart meter,10A,100A,500A,1000A,3000A,6000A optional
Xtester-ME231 Three-phase multifunctional smart meter,10A,100A,500A,1000A,3000A,6000A optional
Xtester-ME231 Three-phase multifunctional smart meter,10A,100A,500A,1000A,3000A,6000A optional

Xtester-ME231 Three-phase multifunctional smart meter,10A,100A,500A,1000A,3000A,6000A optional

2024-06-14 14:49:15  

Xtester-ME231 Three-phase multifunctional smart meter,10A,100A,500A,1000A,3000A,6000A optional

  • Main Features :
  • Serial No. : Xtester2400939
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

Xtester-ME231 Three-phase multifunctional smart meter,10A,100A,500A,1000A,3000A,6000A optional

Overview

The ME231 is a DIN-Rail three-phase multifunctional smart meter that supports externally connected with open type Rogowski coil or voltage type CT, it can realize none dismantling wire test, simplify test steps, save construction cost, and is more convenient for engineering test as well as the inspection and maintenance of distribution system.

 

The ME231 support systems of single-phase and three-phase. It can measure multiple electrical parameters such as current, voltage, power factor, harmonics, power, energy and other electrical parameters of L1,L2,L3.The standard RS485 communication interface can be compatible with various configuration systems through the standard MODBUS-RTU protocol.

Technical Specification

Instantaneous value

Phase Voltage

U1,U2,U3,AVG

Line Voltage

U12,U23,U31,AVG

Current

I1,I2,I3,AVG,IN

Grid Frequency

F1,F2,F3,∑

Power Factor PF

PF1,PF2,PF3,∑

Fundamental power factor  DPF

DPF1,DPF2,DPF3,∑

Active power

P1,P2,P3,∑

Reactive power

Q1,Q2,Q3,∑

Apparent power

S1,S2,S3,∑

Energy

Active energy Pos.

EP1,EP2,EP3,∑

Active Energy Neg.

EP1,EP2,EP3,∑

Reactive Energy Pos.

EQ1,EQ2,EQ3,∑

Reactive energy Neg.

EQ1,EQ2,EQ3,∑

Apparent Energy

ES1,ES2,ES3,∑

Tariff Energy

ET1,ET2, ET3,ET4, ET5,ET6

Harmonics

Voltage Harmonic Distortion

THD (Total harmonic percentage), TOHD (Odd total harmonic percentage), TEHD (Even total harmonic percentage), phase L1.L2.L3 1-50th harmonic percentage, phase ABC 1-50th harmonic voltage value

Voltage Harmonic Value

Current Harmonic Distortion

THD (Total harmonic percentage), TOHD (Odd total harmonic percentage), TEHD (Even total harmonic percentage), phase L1.L2.L3 1- 50th  harmonic percentage, phase ABC 1-50th harmonic current value

Current Harmonic Value

Phasor diagram

Phasor diagram

between voltage and current

Phase Sequence

 voltage and current

Voltage Angle

U1,U2,U3

Current Angle

I1,I2,I3

UI Angle

UI1,UI2,UI3

Demand

Demand

P,Q,S

Active power DMD Max.

P and Time

Reactive power DMD Max.

Q and Time

Apparent power DMD Max.

S and Time

Unbalance

Voltage unbalance

Negative Sequence, zero Sequence

current unbalance

Negative Sequence, zero Sequence

Max.&Min.

Phase Voltage 

U1,U2,U3,AVG

Line Voltage

U12,U23,U31,AVG

Current

I1,I2,I3,AVG,IN

Active power

P1,P2,P3,∑

Reactive power

Q1,Q2,Q3,∑

Apparent power

S1,S2,S3,∑


Telephone