China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xtester-HMBK-10Z OLCT Controller,Automatic Voltage Regulator
Xtester-HMBK-10Z OLCT Controller,Automatic Voltage Regulator
Xtester-HMBK-10Z OLCT Controller,Automatic Voltage Regulator
Xtester-HMBK-10Z OLCT Controller,Automatic Voltage Regulator
Xtester-HMBK-10Z OLCT Controller,Automatic Voltage Regulator
Xtester-HMBK-10Z OLCT Controller,Automatic Voltage Regulator

Xtester-HMBK-10Z OLCT Controller,Automatic Voltage Regulator

2025-06-27 15:01:08  

Xtester-HMBK-10Z OLCT Controller,Automatic Voltage Regulator

  • Main Features :
  • Serial No. : monica0683
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

Xtester-HMBK-10Z OLCT Controller,Automatic Voltage Regulator

General

Main application

HMBK-10Z and HMBK-35Z Automatic Voltage Regulator (hereinafter is called AVR as abbreviation)is a kind of controlling device,which is mainly used to control switching operation by motor drivemechanism on the OLTC. Thus, it can regulate the transformer by manual, by automatic, by parallelcontrol, or by MDU.

Main characteristics

By lightly pressing a button, certain parameters of the AVR can be set, including set voltage, voltageregulating accuracy, time-delay and etc. 

The AVR can display signal voltage, operation times, tap changer position and No. of parallel device. 

The AVR has the function of connection and operation mode non-source contact output, BCD codecontact output as well as one-to-one corresponding position signal non-source contact output. 

The remotecontrol ‘1-N’, ‘N-1’ and ‘Stop’ which can help realizing remote monitoring and controlling of the OLTCby contact point.

It can also realize non-contact remote monitoring and controlling of the tap changerthrough RS-485 communication interface, which communicates with upstream device to achieve remotecontrolling and communication. 

Furthermore, it can be done by remote controlling signal of current tapposition, voltage, connection and operation mode.The AVR has also the function of alarm and runningsignal non-source contact output. 

The AVR has operation connection NC (normally closed) contact input. Only if the contact closes, theAVR works. Sound and light alarm blocks the AVR operation because under voltage protection whencurrent voltage is less than set voltage by 70%. 

On the other side, the alarm blocks the AVR operationbecause over voltage protection when current voltage is high than set voltage by 30%.

Operation environment

1 The AVR must be installed indoors; 
2 Ambient temperature should be neither bellow-10℃ nor above+40℃; 
3 Relative humidity should never exceed 85%; 
4 Altitude is not higher than 2,000m; 
5 Obvious vibration and violent shock repulsion are not allowed; 
6 No explosion hazard. no metal corrosive and no insulation-destroying gases or electric-conduction dustaround. 
7 No erosion by rain and snow.

图片关键词


Telephone
Email
Map
QQ Chat