China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xtester- HDP4000 Series High performance four-channel programmable linear DC regulated power supply
Xtester- HDP4000 Series High performance four-channel programmable linear DC regulated power supply
Xtester- HDP4000 Series High performance four-channel programmable linear DC regulated power supply
Xtester- HDP4000 Series High performance four-channel programmable linear DC regulated power supply
Xtester- HDP4000 Series High performance four-channel programmable linear DC regulated power supply
Xtester- HDP4000 Series High performance four-channel programmable linear DC regulated power supply

Xtester- HDP4000 Series High performance four-channel programmable linear DC regulated power supply

2025-03-03 00:19:01  

HDP4000 Series High performance four-channel programmable linear DC regulated power supply

  • Main Features :
  • Serial No. : Zoe692
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

Xtester- HDP4000 Series High performance four-channel programmable linear DC regulated power supply

 

Four-channel programmable linear DC regulated power supply, 245W output power, electrical isolation between channels, four channels continuously adjustable.

The HDP4000S series supports rear output, making it easy to test system wiring, with a 2-wire/4-wire display mode.

4.3-inch color display, real-time display voltage/current/power values and waveform, which makes the output status and trend clear at a glance.

High resolution: 1 mV, 1 mA; HDP4000S series resolution: 0.1 mV, 1UA.

Low ripple noise: < 350 μVrms / 2 mVpp.

Transient response time: ≤50μs.

Over voltage/over current/over temperature/short circuit protection functions. The over voltage and over current parameters can be flexibly set to achieve effective load protection.

Intelligent temperature control fan automatically adjusts the speed, effectively reducing fan noise.

The use of color and numeric identifiers makes it easy for users to identify information relevant to the output of a particular channel.

Provide 10 groups of storage for sequence/delay/record/panel condition settings.

List function. By editing the single-step voltage, current, time, list function can generate a variety of complex sequences to meet the complicated test requirements.

Recorder function. The recorder can record the output voltage, current and power, and display them by graph.

Keyboard lock function to prevent misoperation.

Support SCPI remote command control.

Support U disk (FAT32 format, Flash) storage, one-click screenshot and data recording function.

Standard configuration ports: USB HOST, USB DEVICE, LAN, digital I/O interface, RS232/RS485 (HDP4324B/HDP4424B), GPIB (HDP4324H/HDP4424H).

Dc output (0℃ ~ 40℃)

Channel

voltage

current

HDP43XX

CH1

32V

3.2 A

CH2

32V

3.2 A

CH3

8V

5A

HDP44XX

CH1

32V

3.2 A

CH2

32V

3.2 A

CH3

8V

2A

CH4

16V

1.5 A

Series-parallel output

Channel

Series

parallel

HDP43XX

CH1

64 v, 3.2 A

32 v, 6.4 A

CH2

CH3

-

-

HDP44XX

CH1

64 v, 3.2 A

32 v, 6.4 A

CH2

CH3

-

-

CH4

-

-

Load regulation rate ± (output percentage + bias)

Voltage

< 0.01% + 2 mV

Current

< 0.01% + 250 μA

Linear regulation rate ± (output percentage + bias)

Voltage

< 0.01% + 2 mV

Current

< 0.01% + 250 μA

Ripple and noise (20Hz ~ 20MHz)

Norm voltage

< 350 μVrms/ 2 mVpp

Accuracy (25℃±5℃) ± (output percentage + bias)

Channel

programming

read-back

voltage

current

voltage

current

HDP43XX

CH1

0.05% + 10 mV

0.2% + 5 mA

0.05% + 10 mV

0.2% + 5 mA

CH2

CH3

0.1% + 5 mV

0.1% + 10 mA

0.1% + 5 mV

0.1% + 10 mA

HDP44XX

CH1

0.05% + 10 mV

0.2% + 5 mA

0.05% + 10 mV

0.2% + 5 mA

CH2

CH3

0.1% + 5 mV

0.1% + 10 mA

0.1% + 5 mV

0.1% + 10 mA

CH4

Transient response time

The time for the output current changing from full load to half load, or from half load to full load, and the output voltage returning to 15mV is less than 50μs.

Machinery

Size

232*153*392 mm

Weight

HDP43XX

9.15 Kg

HDP44XX

9.45 Kg

Power supply

Ac input (50Hz to 60Hz)

100Vac±10%, 115Vac±10%, 230Vac±10% (Max. 250Vac)

Maximum input power

600VA

Environment

Cooling method

Air cooling

Working temperature

0 ℃ to 50 ℃

Storage temperature

- 40 ℃ ~ 70 ℃

Humidity

0℃ to 30℃ : ≤95% relative humidity

30℃ to 40℃ : ≤75% relative humidity

40 ° C to 50 ° C: ≤45% relative humidity

Altitude

Below 3000 metres

 

 


Telephone
Email
Map
QQ Chat