China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xtester-EL Series High-density Programmable DC Electronic Load
Xtester-EL Series High-density Programmable DC Electronic Load
Xtester-EL Series High-density Programmable DC Electronic Load
Xtester-EL Series High-density Programmable DC Electronic Load
Xtester-EL Series High-density Programmable DC Electronic Load
Xtester-EL Series High-density Programmable DC Electronic Load
Xtester-EL Series High-density Programmable DC Electronic Load
Xtester-EL Series High-density Programmable DC Electronic Load

Xtester-EL Series High-density Programmable DC Electronic Load

2023-12-12 13:19:34  

Xtester-EL Series High-density Programmable DC Electronic Load

  • Main Features :
  • Serial No. : Xtester2300521
Contact US For Quotation  Email:mewoi009@mewoi.com  Whatsapp&Wechat:+8619925688679

Xtester-EL Series High-density Programmable DC Electronic Load

INTRODUCTION

This series High-density Programmable DC Electronic Load provides four voltage ranges 40V/200V/600V/1200V. With industry-leading ultra-high power density technology, 4U height can reach 8.1kw.Supports CV, CC, CR and CP these 4 basic operating modes, as well as CV+CC, CV+CR, CR+CC these 3 complex operating modes. Full protection includings OCP, OPP, OTP, over voltage and reverse alarm. Support external control and monitor mode, the 0 to 10V input or output signal represent 0 to full range voltage or current. Provide OCP test, OPP test and Short circuit simulation to effectively solve the application demands for power and automated testing. Built-in RS232, RS485 and USB communication interfaces, LAN&GPIB communication card is optional. Two or more loads can be connected in master-slave parallel mode to provide more power or current capacity. This series DC load can be applied to battery discharge, DC charging station and power electronics and other electronics products.

Product Features

  1. Flippable front panel and color touch screen allow convenient access and operation

  2. Dynamic frequency sweep function for determining worst case voltage peaks*

  3. Non linear load mode function makes the simulated loading current more realistic*

  4. Short circuit test mode

  5. Supports external analog control function

  6. V-monitor/I-monitor

  7. Adjustable current slew rate, adjustable CV loop speed

  8. LED load simulation function

  9. Ultra high precision voltage & current measurement

  10. Full protection: OCP, OPP, OTP, over voltage and reverse alarm

  11. OCP/OPP testing function

  12. Maximum power point tracking*

  13. 50kHz high-speed CC/CR dynamic mode

  14. Up to 20 units master/slave parallel control

  15. 500kHz high-speed voltage and current sampling rate

  16. Timing & discharging measurement for batteries

  17. Front panel USB interface supports data import and export

  18. Smart fan control with lower noise and better for environment

  19. SCPI language and standard rack size make it ideal for ATE System integration

  20. Multi versions to meet the cost performance and different applications

  21. Provides four kinds of basic working mode such as CV/CC/CR/CP, and CV+CC/CV+CR/CR+CC 

  22. complex operating modes

  23. Auto mode function provides an easy way to do complicated tes

  24. * Only professional Electronic Load units support these function

Function & Advantage                         

图片关键词

Flippable Front Panel and Color Touch Screen

This series High Power DC Load is equipped with flippable front panel for 4U, 7U, 10U and 13U height models. Together with a large color touch screen provides simple and fast operation for customer. Real-time update of display input data, status and graphical display makes it more intuitive.  

 图片关键词

Multiple Operating Mode

图片关键词

Adjustable CV Loop Speed

This series electronic load supports CV loop response speed setting to FAST, NORMAL or SLOW to satisfy different test requirements. This function may avoid the inaccurate measurement or testing fail caused by the response speed mismatch between the load and the power supply, which is possible to improve test efficiency and reduce costs on the equipments, time and expenses.

图片关键词

Dynamic Load

This series electronic load can be switched quickly between different values in the same operating mode, including CC dynamic mode, CV dynamic mode, CR dynamic mode and CP dynamic mode, CC/CR high speed dynamic mode up to 50kHz. This function is suitable for transient test of power supply, test of battery protection characteristic and battery pulse charging etc. Dynamic mode test has continuous mode, pulse mode and toggle mode.

图片关键词

Sine Wave Dynamic Load

This series electronic load supports sine wave loading function which allows to load sine wave, can be used for impedance analysis test of fuel cells.

图片关键词

Dynamic Frequency Sweep Function

This series electronic load provides a unique constant current dynamic sweep to use frequency conversion to find out the UUT voltage of worst case. This CC dynamic sweep allows the user to edit two load levels, start frequency, end frequency, step frequency, dwell etc. The sampling rate is up to 500kHz, which make it can simulate different loading conditions for most test requirements.

图片关键词

Maximum power point tracking (MPPT)

It can be applied to track the maximum power point of solar panels. Through the maximum power point tracking method, the maximum power point of the solar panel can be dynamically searched all the time, which can maximize the effectiveness of solar panels.

图片关键词

RLC

Simulating capacitive loads makes the current draw closer to the real situation. It is mainly applied for simulating capacitive loads turn on and turn off test. It can prevent the power supply from charging the capacitors on the motherboard when the power is turned on suddenly, which will cause the inrush current to trigger the power supply over-current protection and make the power supply fail to start smoothly. 

图片关键词

Battery Discharge Test

This series electronic load has battery discharge function, and can perform discharge test under CC, CR or CP mode. The DC load can set end volatge or time to stop loading correctly and make sure the battery is not damaged due to over discharge. The user can set stop conditions, whenever met any condition, the load will stop loading and counting automatically. During the test, users can observe battery's voltage, discharging time and already-discharged-capacity.   

图片关键词

Auto Mode

This mode allows automatically switches among CV, CR, CC and CP modes. It is suitable for lithium ion battery charger testing to get a complete V-I charging curve. This flexible auto mode also enormously improve test efficiency.

图片关键词

OCP/OPP Tests

This series electronic load provides OCP and OPP modes are mainly applied in over-current and over-power points tests. After the testing the load can automatically judge the test result according to the set specifications. Take OPP testing as example, the OPP provides ramped up power for the load to test the UUT voltage whether has reached trigger voltage level and to judge if the protection is acting normally or not.   

List Mode


The list function allows user to create waveform files to automatically simulate various complicated loading conditions. The list mode has 10 files, by editing operating mode (including CC, CV, CR ,CP, Short and ON/OFF), repeat times, total steps, setting value of each step and step time etc. This function can be applied to the testing of output characteristic and stability for power supply.  

图片关键词


Master/Slave Control

This series electronic load provides the user with Master/slave mode, supports parallel connection under different power and same voltage and dynamically synchronized. In Master/slave mode, the user only need to control the master one, the load current will be automatically calculated and downloaded to the slave loads. The Master/slave mode greatly simplifies the operation when increased power is needed.

图片关键词

External Control and Current/Voltage Monitoring

This series electronic load has analog control interface to control the input voltage and current. The external signal 0 to 10V controls the sinking condition from 0 to full scale. Using the external control mode can simulate arbitrary waveform which is ideal for industrial control requirement. The 0 to 10V analog output signal of V-MON/I-MON terminals represent input to which the terminals belong from 0 to full range. An external voltmeter or oscilloscope can be connected to display input voltage/current change.

图片关键词


图片关键词

Model Voltage Current Power Voltage Resolution Current Resolution Voltage Accuracy Current Accuracy Size
EL40VDC3400W40V620A3400W0.1mV0.5mA0.015%+0.015%F.S.0.1%+0.05%F.S.3U
EL40VDC4400W40V800A4400W0.1mV0.5mA0.015%+0.015%F.S.0.1%+0.05%F.S.3U
EL40VDC5600W40V1020A5600W0.1mV1mA0.015%+0.015%F.S.0.1%+0.05%F.S.3U
EL40VDC6600W40V1200A6600W0.1mV1mA0.015%+0.015%F.S.0.1%+0.05%F.S.4U
EL200VDC600W200V60A600W0.1mV0.1mA0.015%+0.015%F.S.0.04%+0.04%F.S.2U
EL200VDC1200W200V130A1200W0.1mV0.1mA0.015%+0.015%F.S.0.04%+0.04%F.S.2U
EL200VDC1800W200V190A1800W0.1mV0.1mA0.015%+0.015%F.S.0.04%+0.04%F.S.2U
EL200VDC2400W200V260A2400W0.1mV0.5mA0.015%+0.015%F.S.0.04%+0.04%F.S.2U
EL200VDC3000W200V320A3000W0.1mV0.5mA0.015%+0.015%F.S.0.04%+0.04%F.S.2U
EL200VDC3400W200V370A3400W0.1mV0.5mA0.015%+0.015%F.S.0.04%+0.04%F.S.3U
EL200VDC4400W200V480A4400W0.1mV0.5mA0.015%+0.015%F.S.0.04%+0.04%F.S.3U
EL200VDC5600W200V610A5600W0.1mV0.5mA0.015%+0.015%F.S.0.04%+0.04%F.S.3U
EL200VDC6600W200V720A6600W0.1mV0.5mA0.015%+0.015%F.S.0.04%+0.04%F.S.4U
EL200VDC8100W200V720A8100W0.1mV0.5mA0.015%+0.015%F.S.0.04%+0.04%F.S.4U
EL200VDC8800W200V960A8800W0.1mV1mA0.015%+0.015%F.S.0.04%+0.04%F.S.7U
EL200VDC10300W200V960A10300W0.1mV1mA0.015%+0.015%F.S.0.04%+0.04%F.S.7U
EL200VDC11000W200V1200A11000W0.1mV1mA0.015%+0.015%F.S.0.04%+0.04%F.S.7U
EL200VDC12500W200V1200A12500W0.1mV1mA0.015%+0.015%F.S.0.04%+0.04%F.S.7U
EL200VDC13200W200V1440A13200W0.1mV1mA0.015%+0.015%F.S.0.04%+0.04%F.S.7U
EL200VDC14700W200V1440A14700W0.1mV1mA0.015%+0.015%F.S.0.04%+0.04%F.S.7U
EL200VDC15400W200V1680A15400W0.1mV2mA0.015%+0.015%F.S.0.04%+0.04%F.S.10U
EL200VDC16900W200V1680A16900W0.1mV2mA0.015%+0.015%F.S.0.04%+0.04%F.S.10U
EL200VDC17600W200V1920A17600W0.1mV2mA0.015%+0.015%F.S.0.04%+0.04%F.S.10U
EL200VDC19100W200V1920A19100W0.1mV2mA0.015%+0.015%F.S.0.04%+0.04%F.S.10U
EL200VDC19800W200V2160A19800W0.1mV2mA0.015%+0.015%F.S.0.04%+0.04%F.S.10U
EL200VDC21300W200V2160A21300W0.1mV2mA0.015%+0.015%F.S.0.04%+0.04%F.S.10U
EL200VDC22000W200V2400A22000W0.1mV4mA0.015%+0.015%F.S.0.04%+0.04%F.S.13U
EL200VDC23500W200V2400A23500W0.1mV4mA0.015%+0.015%F.S.0.04%+0.04%F.S.13U
EL200VDC24200W200V2640A24200W0.1mV4mA0.015%+0.015%F.S.0.04%+0.04%F.S.13U
EL200VDC25700W200V2640A25700W0.1mV4mA0.015%+0.015%F.S.0.04%+0.04%F.S.13U
EL200VDC26400W200V2880A26400W0.1mV4mA0.015%+0.015%F.S.0.04%+0.04%F.S.13U
EL200VDC27900W200V2880A27900W0.1mV4mA0.015%+0.015%F.S.0.04%+0.04%F.S.13U
EL600VDC600W600V40A600W0.5mV0.1mA0.015%+0.015%F.S.0.04%+0.04%F.S.2U
EL600VDC1200W600V90A1200W0.5mV0.1mA0.015%+0.015%F.S.0.04%+0.04%F.S.2U
EL600VDC1800W600V130A1800W0.5mV0.1mA0.015%+0.015%F.S.0.04%+0.04%F.S.2U
EL600VDC2400W600V180A2400W0.5mV0.2mA0.015%+0.015%F.S.0.04%+0.04%F.S.2U
EL600VDC3000W600V220A3000W0.5mV0.2mA0.015%+0.015%F.S.0.04%+0.04%F.S.2U
EL600VDC3400W600V250A3400W0.5mV0.4mA0.015%+0.015%F.S.0.04%+0.04%F.S.3U
EL600VDC4400W600V320A4400W0.5mV0.4mA0.015%+0.015%F.S.0.04%+0.04%F.S.3U
EL600VDC5600W600V410A5600W0.5mV0.4mA0.015%+0.015%F.S.0.04%+0.04%F.S.3U
EL600VDC6600W600V480A6600W0.5mV0.5mA0.015%+0.015%F.S.0.04%+0.04%F.S.4U
EL600VDC8100W600V600A8100W0.5mV0.5mA0.015%+0.015%F.S.0.04%+0.04%F.S.4U
EL600VDC8800W600V640A8800W0.5mV0.5mA0.015%+0.015%F.S.0.04%+0.04%F.S.7U
EL600VDC10300W600V760A10300W0.5mV0.5mA0.015%+0.015%F.S.0.04%+0.04%F.S.7U
EL600VDC11000W600V800A11000W0.5mV1mA0.015%+0.015%F.S.0.04%+0.04%F.S.7U
EL600VDC12500W600V920A12500W0.5mV1mA0.015%+0.015%F.S.0.04%+0.04%F.S.7U
EL600VDC13200W600V960A13200W0.5mV1mA0.015%+0.015%F.S.0.04%+0.04%F.S.7U
EL600VDC14700W600V1080A14700W0.5mV1mA0.015%+0.015%F.S.0.04%+0.04%F.S.7U
EL600VDC15400W600V1120A15400W0.5mV1mA0.015%+0.015%F.S.0.04%+0.04%F.S.10U
EL600VDC16900W600V1240A16900W0.5mV1mA0.015%+0.015%F.S.0.04%+0.04%F.S.10U
EL600VDC17600W600V1280A17600W0.5mV1mA0.015%+0.015%F.S.0.04%+0.04%F.S.10U
EL600VDC19100W600V1400A19100W0.5mV1mA0.015%+0.015%F.S.0.04%+0.04%F.S.10U
EL600VDC19800W600V1440A19800W0.5mV2mA0.015%+0.015%F.S.0.04%+0.04%F.S.10U
EL600VDC21300W600V1560A21300W0.5mV2mA0.015%+0.015%F.S.0.04%+0.04%F.S.10U
EL600VDC22000W600V1600A22000W0.5mV2mA0.015%+0.015%F.S.0.04%+0.04%F.S.13U
EL600VDC23500W600V1720A23500W0.5mV2mA0.015%+0.015%F.S.0.04%+0.04%F.S.13U
EL600VDC24200W600V1760A24200W0.5mV2mA0.015%+0.015%F.S.0.04%+0.04%F.S.13U
EL600VDC25700W600V1880A25700W0.5mV2mA0.015%+0.015%F.S.0.04%+0.04%F.S.13U
EL600VDC26400W600V1920A26400W0.5mV2mA0.015%+0.015%F.S.0.04%+0.04%F.S.13U
EL600VDC27900W600V2040A27900W0.5mV2mA0.015%+0.015%F.S.0.04%+0.04%F.S.13U
EL1200VDC1200W1200V45A1200W1mV0.1mA0.015%+0.015%F.S.0.04%+0.04%F.S.2U
EL1200VDC2400W1200V90A2400W1mV0.1mA0.015%+0.015%F.S.0.04%+0.04%F.S.2U
EL1200VDC3400W1200V125A3400W1mV0.2mA0.015%+0.015%F.S.0.04%+0.04%F.S.3U
EL1200VDC4400W1200V160A4400W1mV0.2mA0.015%+0.015%F.S.0.04%+0.04%F.S.3U
EL1200VDC5600W1200V205A5600W1mV0.2mA0.015%+0.015%F.S.0.04%+0.04%F.S.3U
EL1200VDC6600W1200V240A6600W1mV0.2mA0.015%+0.015%F.S.0.04%+0.04%F.S.4U
EL1200VDC8800W1200V320A8800W1mV0.4mA0.015%+0.015%F.S.0.04%+0.04%F.S.7U
EL1200VDC11000W1200V400A11000W1mV0.4mA0.015%+0.015%F.S.0.04%+0.04%F.S.7U
EL1200VDC13200W1200V480A13200W1mV0.4mA0.015%+0.015%F.S.0.04%+0.04%F.S.7U
EL1200VDC15400W1200V560A15400W1mV0.5mA0.015%+0.015%F.S.0.04%+0.04%F.S.10U
EL1200VDC17600W1200V640A17600W1mV0.5mA0.015%+0.015%F.S.0.04%+0.04%F.S.10U
EL1200VDC19800W1200V720A19800W1mV0.5mA0.015%+0.015%F.S.0.04%+0.04%F.S.10U
EL1200VDC22000W1200V800A22000W1mV1mA0.015%+0.015%F.S.0.04%+0.04%F.S.13U
EL1200VDC24200W1200V880A24200W1mV1mA0.015%+0.015%F.S.0.04%+0.04%F.S.13U
EL1200VDC26400W1200V960A26400W1mV1mA0.015%+0.015%F.S.0.04%+0.04%F.S.13U