2023-07-14 10:23:23  

Fully Automated Production Line Testing of Large Packs for xEVs or Large Packs of up to 300 V

  • Main Features :
  • Serial No. :
Contact Us for QuotationEmail: mewoi008@mewoi.comWhatsapp:+8619928420370

Key Features

  • Simultaneous measurement of internal resistance and open circuit voltage.

  • Fully automated production line testing of large packs for xEVs or large packs of up to 300 V.

  • Resistance measurement ranges: 3 mΩ/30 mΩ/300 mΩ/3 Ω/30 Ω/300 Ω/3 kΩ

  • Voltage measurement ranges: 6 V/60 V/300 V

  • Equipped with LAN


Basic specifications

Resistance measurement ranges3 mΩ(Max. display: 3.1000 mΩ, resolution: 0.1 μΩ, measurement current: 100 mA)
30 mΩ(Max. display: 31.000 mΩ, resolution: 1 μΩ, measurement current: 100 mA)
300 mΩ(Max. display: 310.00 mΩ, resolution: 10 μΩ, measurement current: 10 mA)
3 Ω(Max. display: 3.1000 Ω, resolution: 100 μΩ, measurement current: 1 mA)
30 Ω(Max. display: 31.000 Ω, resolution: 1 mΩ, measurement current: 100 μA)
300 Ω(Max. display: 310.00 Ω, resolution: 10 mΩ, measurement current: 10 μA)
3 kΩ(Max. display: 3.1000 kΩ, resolution: 100 mΩ, measurement current: 10 μA)

Basic accuracy: ±0.5% rdg ±10 dgt(3 mΩ range), ±0.5% rdg ±5 dgt(30 mΩ range or more)
Measurement frequency: 1 kHz ±0.2 Hz
Measurement method: AC four-terminal method
Voltage measurement ranges6 V(Max. display: 6.00000 V, resolution: 10 μV)
60 V(Max. display: 60.0000 V, resolution: 100 μV)
300 V(Max. display: 300.000 V, resolution: 1 mV)

Basic accuracy: ±0.01% rdg. ±3 dgt.
Response time10 ms
Sampling periodΩ or V (60 Hz): 4 ms (EX.FAST), 12 ms (FAST), 35 ms (MEDIUM), 150 ms (SLOW)
ΩV (60 Hz): 8 ms (EX.FAST), 24 ms (FAST), 70 ms (MEDIUM), 253 ms (SLOW)

Ω or V (50 Hz): 4 ms (EX.FAST), 12 ms (FAST), 42 ms (MEDIUM), 157 ms (SLOW)
ΩV (50 Hz): 8 ms (EX.FAST), 24 ms (FAST), 84 ms (MEDIUM), 259 ms (SLOW)
FunctionsContact check, Zero adjustment (±1000 counts), Pulse measurement, Comparator (Hi/ IN/ Lo), Statistical calculations (Max. 30,000), Delay, Average, Panel saving/loading, Memory storage, LabVIEW® driver
InterfacesLAN (TCP/IP, 10BASE-T/100BASE-TX)
RS-232C (Max. 38.4 kbps, Available as printer I/F)
EXT I/O (37-pin Handler interface)
Analog output (DC 0 V to 3.1 V)
Power supply100 to 240 V AC, 50 Hz/60 Hz, 35 VA max.
Dimensions and mass215 mm (8.46 in) W × 80 mm (3.15 in) H × 295 mm (11.61 in) D, 2.4 kg (84.7 oz)
Included accessoriesInstruction manual ×1, Power cord ×1, Operating Precautions ×1