Features
• High Power Density: 600 watts in 1U (1.75 inches) high, half rack (8.5 inches) wide; no top or bottom clearance spacing required. • Near Linear Ripple & Noise Ripple as low as 2.5mV rms, noise as low as 15mV p-p. • Remote Control • LXI Compliant Ethernet LAN / RS-232C (16 bit) • IEEE-488.2 / RS-232C (12 bit) • Standard analog programming 0-5V, 0-10V, or 0-5kΩ . |
DLM 600 Series : Product Specifications
Common | |
Remote Sense | The maximum load line drop is up to the full voltage rating of the supply. The drop in the load leads subtracts from the maximum voltage available for the load except as follows: maximum rated voltage is available at the load and voltage regulation specifications apply for line drops of<1V on DLM5-75 and DLM8-75, <2V for all other DLM600 models |
Remote Programming | Voltage, current (0-100%) and OVP (5-110%) of full scale can be programmed by selectable 0-5VDC, 0-10VDC, or 0-5kΩ |
Remote Monitoring | Voltage or current can be monitored with user selectable ranges, scaled to 0-5 VDC or 0-10 VDC |
Operational Features | Master/slave parallel operation, up to 4 units of the same model can be connected in parallel, with active current sharing control. Series operation, multiple units of the same model can be connected in series, limited by 300Vpk between either output terminal and chassis. |
Software | IVI-COM, LabVIEW® or LabWindow®/CVI driver for Ethernet and IEEE-488.2 |
Regulatory Compliance | CE Compliant: • Low Voltage Directive (73/23/EEC) using EN 61010-1, and • EMC Directive (89/336/EEC) using EN 61326 Certified to UL 61010-1,CSA C22.2 No. 61010.1 and IEC/EN 61010-1 |
Input | |
Voltage and Frequency | 90-132 VAC or 180-264 VAC max, auto ranging, 47-63 Hz,single phase, 2-wire plus ground |
Current | 11A maximum at 115VAC, 6A maximum at 230 VAC |
Connector | IEC 320 with detachable line cord |
Power Factor | 0.6, typical at full load; dependent on the impedance of the AC input. |
Output | |
Line Regulation | Voltage: 0.005% of V max + 2 mV Current: 0.01% of I max + 2 mA See table for input voltage variation over the AC input voltage range, with constant rated load. |
Load Regulation | Voltage: 0.005% of V max + 2 mV Current: 0.02% of I max + 5 mA See table For 0-100% load variation, with constant nominal line voltage |
Transient Response | 500 μs to steady-state output voltage (within 0.1% of Vmax) for 50-100% or 100-50% load change |
Stability | ±0.05% of maximum voltage or current over 8 hours after 30 minute warm-up time at fixed line, load and temperature |
Efficiency | 84% typical at maximum output power; 82% typical for DLM 5-75 and DLM 8-75 |
Temperature Coefficient | 0.02%/°C of maximum output voltage, 0.03%/°C of maximum output current. Change in output per °C change in ambient temperature, with constant line and load. |
Environmental | |
Operating Temperature | 0°C to 50°C (noderating) |
Storage Temperature | -40°C to 65°C |
Cooling | Internal variable speed fans with over temperature protection. Air intake is from the front and sides with exhaust at rear and sides for maximum rackmount packing density. |
Physical | |
Dimensions | Width: 8.5” (216 mm) Height: 1U or 1.75” (44 mm) Depth: 17” (432 mm) Option M6 depth 20” (508 mm) |
Weight | 9.7 lbs. (4.4 kg) |
Shipping Weight | 12.7 lbs. (5.8 kg) |
DLM 600 Series : Product Specifications
Model | Output Ratings | Line Regulation | Load Regulation | |||||||||||||
Voltage (VDC) | Current (ADC) | Power (Watts) | Voltage (0.005% of Vmax + 2 mV) | Current (0.01% of Imax + 2 mA) | Voltage (0.005% of Vmax + 2 mV) | Current (0.02% of Imax + 5 mA) | ||||||||||
DLM 5-75 | 0-5 | 0-75 | 375 | 2.25 mV | 9.5 mA | 2.25 mV | 20 mA | |||||||||
DLM 8-75 | 0-8 | 0-75 | 600 | 2.4 mV | 9.5 mA | 2.4 mV | 20 mA | |||||||||
DLM 10-60 | 0-10 | 0-60 | 600 | 2.5 mV | 8 mA | 2.5 mV | 17 mA | |||||||||
DLM 20-30 | 0-20 | 0-30 | 600 | 3 mV | 5 mA | 3 mV | 11 mA | |||||||||
DLM 40-15 | 0-40 | 0-15 | 600 | 4 mV | 3.5 mA | 4 mV | 8 mA | |||||||||
DLM 60-10 | 0-60 | 0-10 | 600 | 5 mV | 3 mA | 5 mV | 7 mA | |||||||||
DLM 80-7.5 | 0-80 | 0-7.5 | 600 | 6 mV | 2.75 mA | 6 mV | 6.5 mA | |||||||||
DLM 150-4 | 0-150 | 0-4 | 600 | 9.5 mV | 2.4 mA | 9.5 mV | 5.8 mA | |||||||||
DLM 300-2 | 0-300 | 0-2 | 600 | 17 mV | 2.2 mA | 17 mV | 5.4 mA | |||||||||
Model | Programming Accuracy‡ | Display Accuracy | ||||||||||||||
Ethernet (M130/M131) | GPIB (M9G/M85) | |||||||||||||||
Voltage (0.1% of VMax) | Current (0.25% of IMax) | Power (0.5% of 1.1 x Vmax) | Voltage (0.2% of VMax) | Current (0.5% of IMax) | OVP (1.0% of 1.1 x Vmax) | Voltage (0.5% of Vmax + 1 count) | Current (1.0% of Imax + 1 count) | |||||||||
DLM 5-75 | 5 mV | 188 mA | 44 mV | 16 mV | 375 mA | 55 mV | 35 mV | 850 mA | ||||||||
DLM 8-75 | 8 mV | 188 mA | 44 mV | 16 mV | 375 mA | 88 mV | 50 mV | 850 mA | ||||||||
DLM 10-60 | 10 mV | 150 mA | 55 mV | 20 mV | 300 mA | 110 mV | 60 mV | 700 mA | ||||||||
DLM 20-30 | 20 mV | 75 mA | 110 mV | 40 mV | 150 mA | 220 mV | 200 mV | 400 mA | ||||||||
DLM 40-15 | 40 mV | 38 mA | 220 mV | 80 mV | 75 mA | 440 mV | 300 mV | 260 mA | ||||||||
DLM 60-10 | 60 mV | 25 mA | 330 mV | 120 mV | 50 mA | 660 mV | 400 mV | 210 mA | ||||||||
DLM 80-7.5 | 80 mV | 19 mA | 440 mV | 160 mV | 38 mA | 880 mV | 500 mV | 85 mA | ||||||||
DLM 150-4 | 150 mV | 10 mA | 825 mV | 300 mV | 20 mA | 1.65 V | 850 mV | 50 mA | ||||||||
DLM 300-2 | 300 mV | 5 mA | 1.65 V | 600 mV | 10 mA | 3.3 V | 2.5 V | 30 mA | ||||||||
‡ Readback accuracy is the same as programming accuracy for all parameters except GPIB Voltage readback which is 0.25% of VMax | ||||||||||||||||
Model | Ripple and Noise, Voltage Mode | OVP Adjustment Range (5% - 110% of Vmax) | Stability | Temperature Coefficient | Maximum Total Remote Sense Drop | |||||||||||
Ripple (rms)* | Noise (p-p)* | Voltage (0.05% of Vmax) | Current (0.05% of Imax) | Voltage (0.02%/°C of Vmax) | Current (0.03%/°C of Imax) | |||||||||||
DLM 5-75 | 5 mV | 30 mV | 0.25-5.5 V | 2.5 mV | 37.5 mA | 1 mV/°C | 22.5 mA/°C | 1V | ||||||||
DLM 8-75 | 5 mV | 30 mV | 0.4-8.8 V | 4 mV | 37.5 mA | 1.6 mV/°C | 22.5 mA/°C | 1V | ||||||||
DLM 10-60 | 5 mV | 30 mV | 0.5-11 V | 5 mV | 30 mA | 2 mV/°C | 18 mA/°C | 2V | ||||||||
DLM 20-30 | 2.5 mV | 15 mV | 1-22 V | 10 mV | 15 mA | 4 mV/°C | 9 mA/°C | 2V | ||||||||
DLM 40-15 | 2.5 mV | 15 mV | 2-44 V | 20 mV | 7.5 mA | 8 mV/°C | 4.5 mA/°C | 2V | ||||||||
DLM 60-10 | 2.5 mV | 20 mV | 3-66 V | 30 mV | 5 mA | 12 mV/°C | 3 mA/°C | 2V | ||||||||
DLM 80-7.5 | 4 mV | 20 mV | 4-88 V | 40 mV | 3.8 mA | 16 mV/°C | 2.25 mA/°C | 2V | ||||||||
DLM 150-4 | 7 mV | 40 mV | 7.5-165 V | 75 mV | 2 mA | 30 mV/°C | 1.2 mA/°C | 2V | ||||||||
DLM 300-2 | 10 mV | 60 mV | 15-330 V | 150 mV | 1 mA | 60 mV/°C | 0.6 mA/°C | 2V | ||||||||
* rms noise typical from 20 Hz to 20 MHz Specifications subject to change |