  • Main Features :
  • Serial No. : Xtester2300539
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

Xtester-AMETEK Sorensen DLM 600 - 1/2 Rack Programmable DC Power Supplies,Half Rack Programmable DC Power Supply

Features

• High Power Density:  600 watts in 1U (1.75 inches) high, half rack (8.5 inches) wide; no top or bottom clearance spacing required.

• Near Linear Ripple & Noise Ripple as low as 2.5mV rms, noise as low as 15mV p-p.

• Remote Control

• LXI Compliant Ethernet LAN / RS-232C (16 bit)

• IEEE-488.2 / RS-232C (12 bit)

• Standard analog programming 0-5V, 0-10V, or 0-5kΩ .

DLM 600 Series : Product Specifications

Common

Remote Sense

The maximum load line drop is up to the full voltage rating of the supply. The drop in the load leads subtracts from the maximum voltage available for the load except as follows: maximum rated voltage is available at the load and voltage regulation

specifications apply for line drops of<1V on DLM5-75 and DLM8-75, <2V for all other DLM600 models

Remote Programming

Voltage, current (0-100%) and OVP (5-110%) of full scale can be programmed by selectable 0-5VDC, 0-10VDC, or 0-5kΩ

Remote Monitoring

Voltage or current can be monitored with user selectable ranges, scaled to 0-5 VDC or 0-10 VDC

Operational Features

Master/slave parallel operation, up to 4 units of the same model can be connected in parallel, with active current sharing control.    Series operation, multiple units of the same model can be connected in series, limited by 300Vpk between either output terminal and chassis.

Software

IVI-COM, LabVIEW® or LabWindow®/CVI driver for Ethernet and IEEE-488.2

Regulatory Compliance

CE Compliant:

• Low Voltage Directive (73/23/EEC) using EN 61010-1, and

• EMC Directive (89/336/EEC) using EN 61326 Certified to UL 61010-1,CSA C22.2 No. 61010.1 and IEC/EN 61010-1

Input

Voltage and Frequency

90-132 VAC or 180-264 VAC max, auto ranging, 47-63 Hz,single phase, 2-wire plus ground

Current

11A maximum at 115VAC, 6A maximum at 230 VAC

Connector

IEC 320 with detachable line cord

Power Factor

0.6, typical at full load; dependent on the impedance of the AC input.

Output

Line Regulation

Voltage: 0.005% of V max + 2 mV

Current: 0.01% of I max + 2 mA

See table for input voltage variation over the AC input voltage range, with constant rated load.

Load Regulation

Voltage: 0.005% of V max + 2 mV

Current: 0.02% of I max + 5 mA

See table For 0-100% load variation, with constant nominal line voltage

Transient Response

500 μs to steady-state output voltage (within 0.1% of Vmax) for 50-100% or 100-50% load change

Stability

±0.05% of maximum voltage or current over 8 hours after 30 minute warm-up time at fixed line, load and temperature

Efficiency

84% typical at maximum output power; 82% typical for DLM 5-75 and DLM 8-75

Temperature Coefficient

0.02%/°C of maximum output voltage, 0.03%/°C of maximum output current. Change in output per °C change in ambient temperature, with constant line and load.

Environmental

Operating Temperature

0°C to 50°C (noderating)

Storage Temperature

-40°C to 65°C

Cooling

Internal variable speed fans with over temperature protection. Air intake is from the front and sides with exhaust at rear and sides for maximum rackmount packing density.

Physical

Dimensions

Width: 8.5” (216 mm)

Height: 1U or 1.75” (44 mm)

Depth: 17” (432 mm) Option M6 depth 20” (508 mm)

Weight

9.7 lbs. (4.4 kg)

Shipping Weight

12.7 lbs. (5.8 kg)

DLM 600 Series : Product Specifications


 

Model

Output Ratings

Line Regulation

Load Regulation


Voltage

(VDC)

Current

(ADC)

Power

(Watts)

Voltage (0.005%  of Vmax + 2 mV)

Current (0.01% of Imax + 2 mA)

Voltage (0.005%  of Vmax + 2 mV)

Current (0.02% of Imax + 5 mA)

DLM 5-75

0-5

0-75

375

2.25 mV

9.5 mA

2.25 mV

20 mA

DLM 8-75

0-8

0-75

600

2.4 mV

9.5 mA

2.4 mV

20 mA

DLM 10-60

0-10

0-60

600

2.5 mV

8 mA

2.5 mV

17 mA

DLM 20-30

0-20

0-30

600

3 mV

5 mA

3 mV

11 mA

DLM 40-15

0-40

0-15

600

4 mV

3.5 mA

4 mV

8 mA

DLM 60-10

0-60

0-10

600

5 mV

3 mA

5 mV

7 mA

DLM 80-7.5

0-80

0-7.5

600

6 mV

2.75 mA

6 mV

6.5 mA

DLM 150-4

0-150

0-4

600

9.5 mV

2.4 mA

9.5 mV

5.8 mA

DLM 300-2

0-300

0-2

600

17 mV

2.2 mA

17 mV

5.4 mA

 

 

Model

Programming Accuracy‡

Display Accuracy

Ethernet (M130/M131)

GPIB (M9G/M85)

Voltage

(0.1% of

VMax)

Current

(0.25% of

IMax)

Power

(0.5% of 1.1 x Vmax)

Voltage

(0.2% of

VMax)

Current

(0.5% of IMax)

OVP

(1.0% of 1.1 x Vmax)

Voltage

(0.5% of

Vmax

+ 1 count)

Current

(1.0% of Imax + 1 count)

DLM 5-75

5 mV

188 mA

44 mV

16 mV

375 mA

55 mV

35 mV

850 mA

DLM 8-75

8 mV

188 mA

44 mV

16 mV

375 mA

88 mV

50 mV

850 mA

DLM 10-60

10 mV

150 mA

55 mV

20 mV

300 mA

110 mV

60 mV

700 mA

DLM 20-30

20 mV

75 mA

110 mV

40 mV

150 mA

220 mV

200 mV

400 mA

DLM 40-15

40 mV

38 mA

220 mV

80 mV

75 mA

440 mV

300 mV

260 mA

DLM 60-10

60 mV

25 mA

330 mV

120 mV

50 mA

660 mV

400 mV

210 mA

DLM 80-7.5

80 mV

19 mA

440 mV

160 mV

38 mA

880 mV

500 mV

85 mA

DLM 150-4

150 mV

10 mA

825 mV

300 mV

20 mA

1.65 V

850 mV

50 mA

DLM 300-2

300 mV

5 mA

1.65 V

600 mV

10 mA

3.3 V

2.5 V

30 mA

‡ Readback accuracy is the same as programming accuracy for all parameters except GPIB Voltage readback which is 0.25% of VMax

 

Model

Ripple and Noise, Voltage Mode

OVP

Adjustment

Range

(5% - 110% of

Vmax)

Stability

Temperature Coefficient

Maximum

Total Remote

Sense Drop

Ripple

(rms)*

Noise

(p-p)*

Voltage

(0.05% of Vmax)

Current

(0.05% of Imax)

Voltage

(0.02%/°C of Vmax)

Current

(0.03%/°C of Imax)

DLM 5-75

5 mV

30 mV

0.25-5.5 V

2.5 mV

37.5 mA

1 mV/°C

22.5 mA/°C

1V

DLM 8-75

5 mV

30 mV

0.4-8.8 V

4 mV

37.5 mA

1.6 mV/°C

22.5 mA/°C

1V

DLM 10-60

5 mV

30 mV

0.5-11 V

5 mV

30 mA

2 mV/°C

18 mA/°C

2V

DLM 20-30

2.5 mV

15 mV

1-22 V

10 mV

15 mA

4 mV/°C

9 mA/°C

2V

DLM 40-15

2.5 mV

15 mV

2-44 V

20 mV

7.5 mA

8 mV/°C

4.5 mA/°C

2V

DLM 60-10

2.5 mV

20 mV

3-66 V

30 mV

5 mA

12 mV/°C

3 mA/°C

2V

DLM 80-7.5

4 mV

20 mV

4-88 V

40 mV

3.8 mA

16 mV/°C

2.25 mA/°C

2V

DLM 150-4

7 mV

40 mV

7.5-165 V

75 mV

2 mA

30 mV/°C

1.2 mA/°C

2V

DLM 300-2

10 mV

60 mV

15-330 V

150 mV

1 mA

60 mV/°C

0.6 mA/°C

2V

* rms noise typical from 20 Hz to 20 MHz