Contact Us For Quotation | Email: 464560351@qq.com | Whatsapp&Wechat:+8618620373879 |
Xtester-HVL50KV-up to 50KV Pragrammable linear high voltage DC power supply HY-HVL-EN
Overview
This power supply adoptsLinear amplification technology,haveUltra- low interference The advantage of waves and high accuracy,High voltage, low current, mostly used for power semiconductors High voltage performance testing of devices。 |
Features
1,Output voltage range:1.25kV-50kV 2,Current range:500μA-50mA 3,Ultra low interference, ultra-low ripple, suitable for high- precision testing and measurement 4,16 bits D/A High precision converter with precise output 5,20 bits A/D High precision converter for more accurate read back |
APPLICATION Area
A high-voltage high-precision current power supply commonly used for power semiconductor devices, with a voltage of up to 50kV. It conducts voltage withstand and breakdown tests on power semiconductor devices such as IGBT, MOS transistor, diode, silicon carbide device, lithography machine light source, etc |
1,High voltage device breakdown test 2,Diode reverse bias test 3,High voltage component testing 4, Shore based power supply 5,High Energy Physics Research 6,Ion beam power supply 7,High voltage resistivity test 8,High-energy particle injection 9,Insulation and voltage withstand test 10, High voltage amplifier bias 11,EMC Lab 12, Aging of electronic components 13,Power semiconductor testing 14,Power supply for deep-sea 15,observation network 16,X-ray system 17,High voltage direct current 18, transmission,19, ElectroStatic Precipitation, 20,scientific research, 21, laser, 22,Semiconductor, 23,Process, 24,particle accelerator 25,Capacitor charging, 26,chemical purification, 27,pulse power |
Product Selection And Parameters
Select According To Voltage Size | |||
Models | Output voltage | Output current | Output power |
HY-HVL 1.25kV-20 | 1.25kV | 20mA | 25W |
HY-HVL 2.5kV-10 | 2.5kV | 10mA | 25W |
HY-HVL 5kV-5 | 5kV | 5mA | 25W |
HY-HVL 10kV-1 | 10kV | 1mA | 10W |
HY-HVL 15kV-1 | 15kV | 1mA | 15W |
HY-HVL 20kV-0.5 | 20kV | 0.5mA | 10W |
HY-HVL 20kV-1 | 20kV | 1mA | 20W |
HY-HVL 30kV-1 | 30kV | 1mA | 30W |
HY-HVL 40kV-1 | 40kV | 1mA | 40W |
HY-HVL 50kV-1 | 50kV | 1m | 50W |
Constant Voltage Mode(CV Mode)
Voltage adjustable output range | <5kV:0.5%-100% Output Value;≥10kV:1%-100% Output Value |
Input adjustment rate(CV Model) | ≤0.01% F.S. ( AC input 220 V ± 10%, constant load) |
Load regulation(CV Model) | ≤0.01% F.S. (No load to full load, constantinput voltage) |
Ripple wave rms ( 3Hz - 300kHz ) | 0.002%F.S. |
Constant Current Mode(CC Mode)
Settable output range | 0 - Rated output value |
Input adjustment rate(CCModel) | Rated output current 0.01% +2mA(AC input 220 V ± 15%,constant load) |
Load regulation(CC Model) | Rated output current 0.02% +5mA(No load to full load, constantinput voltage) |
Ripple wave rms ( 3Hz - 300kHz ) | 0.002%F.S. |
Programming And Readback Accuracy Resolution
Voltage output programming accuracy | 0.01%+0.05% F.S. |
Current output programming accuracy | 0.02%+0.05% F.S. |
Voltage setting resolution | 0.1V(≤6KV) , 1V( > 6KV) |
Current setting resolution | 0.1μA(≤6mA),1uA(≤60mA) |
Voltage output readback accuracy | Output voltage 0.01%+0.05% |
Current output readback accuracy | Output voltage 0.02%+0.05% |
Voltage read back resolution | 0.01V(≤10kV) , 0.1V( > 10kV) |
Current read back resolution | 0.01μA(≤1mA),0.1uA(≤10mA),1uA(≤100mA) |
Stability Temperature Coefficient
Stability (rated output voltage/current) | U:0.05% | I: | 0.05%(After 30 minutes of power on at a certain input voltage and load ambient temperature, 8 hours) |
Temperature coefficient (rated output voltage/current) | U:200ppm/℃ | I: | 300ppm/℃(After 30 minutes of power on) |
Protection Function
OVP Overvoltage protection setting range | 10 - 110%,Immediate shutdown of output beyond limit |
OCP Overcurrent protection setting range | 0 - 105%,Immediate shutdown of output beyond limit |
OTP Over temperature protection | Immediate shutdown of output beyond limit |
OPP Over power protection | 10 - 110%,Immediate shutdown of output beyond limit |
Ambient Condition
Environment | Indoor use; Installation overvoltage level: II; Pollution level: P2; Class II equipment |
Ambient temperature | 0℃ to 50℃,optional -10℃ to 50℃, -20℃ to 50℃, -40℃ to 50℃ |
Storage environment temperature | -20℃ to 65℃, |
Working environment humidity | 20%-90% RH,No condensation, continuous operation |
Storage environment humidity | 10% - 95% RH,No condensation |
Altitude | Above an altitude of 2000 meters, the power decreases by 2% for every 100 meters increase, or the maximum working environment temperature decreases by 1 ℃ for every 100 meters;When not in operation, it can reach an altitude of 12000 meters |
Burial | Forced air cooling, intelligent variable speed fan, front/side air inlet, rear air outlet |
Noise | ≤ 65dB(A),Weighted measurement with 1 m |
Control Panel
Monitor | 4.7 inch LCD display, touch screen |
Control function |
|
Programming function | Step step、 ladder、Gradient |
Input Power Supply
Frequency | 47 Hz - 63 Hz |
Connection | Single phase two wire+ground wire,220 V ± 15%(-ST Standard configuration model) |
Size
Size | 430(W) * 500(D) * 88(H) mm, 2U 482.6(W) * 660(D) * 133(H) mm, 3U 430(W) * 560(D) * 178(H) mm, 4U Different voltage and power use different chassis |