China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xtester-HVL50KV-up to 50KV Pragrammable Linearhigh voltage DC power supply HY-HVL-EN

Xtester-HVL50KV-up to 50KV Pragrammable Linearhigh voltage DC power supply HY-HVL-EN

2024-04-25 12:05:49  

Xtester-HVL50KV-up to 50KV Pragrammable high voltage DC power supply HY-HVL-EN

  • Main Features :
  • Serial No. : Xtester2400797
Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

Xtester-HVL50KV-up to 50KV Pragrammable linear high voltage DC power supply HY-HVL-EN

Overview

This power supply adoptsLinear amplification technology,haveUltra-    low interference  The advantage of waves and high accuracy,High voltage,  low current, mostly used for power semiconductors   High voltage

performance testing of devices。

Features

1,Output voltage range:1.25kV-50kV

2,Current range:500μA-50mA

3,Ultra low interference, ultra-low ripple, suitable   for high- precision testing and measurement

4,16 bits D/A High precision converter with precise output

5,20 bits A/D High precision converter for more accurate read back

APPLICATION Area

A high-voltage high-precision current power supply commonly used for power

semiconductor devices, with a voltage of up to 50kV. It conducts voltage withstand and breakdown tests on power semiconductor devices such as IGBT, MOS transistor, diode,  silicon carbide device, lithography machine light source, etc

1,High voltage device breakdown test 2,Diode reverse bias test  3,High voltage component testing  4, Shore based power supply    5,High Energy Physics Research  6,Ion beam power supply 7,High voltage resistivity test  8,High-energy particle injection 9,Insulation and voltage withstand test 10, High voltage amplifier bias 11,EMC Lab  12, Aging of electronic components  13,Power semiconductor testing     14,Power supply for deep-sea 15,observation network  16,X-ray system  17,High voltage direct current 18,

transmission,19, ElectroStatic Precipitation, 20,scientific research, 21, laser, 22,Semiconductor, 23,Process, 24,particle accelerator

25,Capacitor charging, 26,chemical purification, 27,pulse power

Product Selection And Parameters

Select According To Voltage Size

Models

Output voltage

Output current

Output power

HY-HVL 1.25kV-20

1.25kV

20mA

25W

HY-HVL 2.5kV-10

2.5kV

10mA

25W

HY-HVL 5kV-5

5kV

5mA

25W

HY-HVL 10kV-1

10kV

1mA

10W

HY-HVL 15kV-1

15kV

1mA

15W

HY-HVL 20kV-0.5

20kV

0.5mA

10W

HY-HVL 20kV-1

20kV

1mA

20W

HY-HVL 30kV-1

30kV

1mA

30W

HY-HVL 40kV-1

40kV

1mA

40W

HY-HVL 50kV-1

50kV

1m

50W

Constant Voltage Mode(CV Mode)

Voltage adjustable output range

<5kV:0.5%-100% Output Value;≥10kV:1%-100% Output Value

Input adjustment rate(CV Model)

≤0.01% F.S.   ( AC input 220 V ± 10%,   constant load)

Load regulation(CV Model)

≤0.01% F.S.   (No load to full load, constantinput voltage)

Ripple wave rms ( 3Hz - 300kHz )

0.002%F.S.

Constant Current Mode(CC Mode)

Settable output range

0 - Rated output value

Input adjustment rate(CCModel)

Rated output current 0.01% +2mA(AC input 220 V ± 15%,constant load)

Load regulation(CC Model)

Rated output current 0.02% +5mA(No load to full load, constantinput voltage)

Ripple wave rms ( 3Hz - 300kHz )

0.002%F.S.

Programming And Readback Accuracy Resolution

Voltage output programming accuracy

0.01%+0.05% F.S.

Current output programming accuracy

0.02%+0.05% F.S.

Voltage setting resolution

0.1V(≤6KV)   , 1V( > 6KV)

Current setting resolution

0.1μA(≤6mA),1uA(≤60mA)

Voltage output readback accuracy

Output voltage 0.01%+0.05%

Current output readback accuracy

Output voltage 0.02%+0.05%

Voltage read back resolution

0.01V(≤10kV)   , 0.1V( > 10kV)

Current read back resolution

0.01μA(≤1mA),0.1uA(≤10mA),1uA(≤100mA)

Stability Temperature Coefficient

Stability (rated output voltage/current)

U:0.05%

I:

0.05%(After 30 minutes of power on at a certain input voltage and load ambient temperature, 8 hours)

Temperature coefficient

(rated output voltage/current)

U:200ppm/℃

I:

300ppm/℃(After 30 minutes of power on)

Protection Function

OVP Overvoltage protection setting range

10 - 110%,Immediate shutdown of output beyond limit

OCP Overcurrent protection setting range

0 - 105%,Immediate shutdown of output beyond limit

OTP Over temperature protection

Immediate shutdown of output beyond limit

OPP Over power protection

10 - 110%,Immediate shutdown of output beyond limit

Ambient Condition

Environment

Indoor use; Installation overvoltage level: II; Pollution level: P2; Class II equipment

Ambient temperature

0℃ to 50℃,optional -10℃  to 50℃,   -20℃  to  50℃,    -40℃  to  50℃

Storage environment temperature

-20℃ to 65℃,

Working environment humidity

20%-90% RH,No condensation, continuous operation

Storage environment humidity

10% - 95% RH,No condensation

Altitude

Above an altitude of 2000 meters, the power decreases by 2% for every 100 meters increase, or the maximum working environment temperature decreases by 1 ℃ for every 100 meters;When not in operation, it can reach  an altitude of 12000 meters

Burial

Forced air cooling, intelligent variable speed fan, front/side air inlet, rear air outlet

Noise

≤ 65dB(A),Weighted measurement with 1 m

Control Panel

Monitor

4.7 inch LCD display, touch screen

Control function



Numeric key input, multi-level shuttle knob adjustment (outer circle coarse adjustment/inner circle fine adjustment),

Programming function

Step step、  ladder、Gradient

Input Power Supply

Frequency

47 Hz - 63 Hz

Connection

Single phase two wire+ground wire,220 V ± 15%(-ST Standard configuration model)

Size


Size

430(W) * 500(D) * 88(H) mm, 2U

482.6(W) * 660(D) * 133(H) mm, 3U

430(W)  * 560(D) * 178(H) mm, 4U

Different voltage and power use different chassis


Telephone
Email
Map
QQ Chat