China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

Xtester-PT740-1A (150kHz,400A) Current probe

Xtester-PT740-1A (150kHz,400A) Current probe

2023-07-13 13:40:10  

Attenuation ratio:1A/10mV,1A/1mV Input:AC:0.2-40A,DC:0.4-40A; AC:40-400A DC:40-400A Big clamp,easy operation.

  • Main Features :
  • Serial No. :
Contact Us for QuotationEmail: mewoi008@mewoi.comWhatsapp:+8619928420370

Xtester-PT740-1A (150kHz,400A) Current probe


INTRODUCTION

Xtester-PT740-1A

- Quick, safe and simple AC/DC current measurement.

- Adopts the Hall effect principle to measure 1400A DC and 1400A AC peak; It is suitable for power measurement and can measure RMS value in the case of DC interference.
- Standard BNC interface, can be customized multimeter dedicated interface.
- There are two power supply modes: battery powered by microcomputer control after 10 minutes of automatic shutdown, adaptor power supply without automatic shutdown function.

Technical Specification

Range

Current measuring range

AC:0.2A~40A peak,

DC:0.4A~40A

AC:40A~400Apeak,

DC:40A~400A

Attenuation

10mV/A(100:1)

1mV/A(1000:1)

Accuracy

DC-1kHz,1.5%±5mV

Noise

1mV rms

Rise/fall time

2.3μs

Bandwidth

DC~150kHz(-3dB)

Load impedance

≥1MΩand≤100pF

Insert impedance

50Hz-0.39mΩ,1000Hz-58mΩ

Working voltage

Max.600V rms

Common mode voltage

Max.600V rms

Jaw opening conductor position influence

0.5% numerical reading

Battery

9V Alkaline battery

Battery capacity indicator

When >6.5V,LED turns green

Battery life

About 50 hour

Overload indicator

LED turn red

Automatic shutdown time

10min(type 1 power supply)

Dc zero adjustment

Jaw opening insert conductor

One cable: dia. 30mm. Two cable :dia.24mm or 2х31.5х10mm bus bar

Size

224х97х44mm

Weight

440g

Color

Dark grey box; Red jaw opening

output

Cable length 2M, BNC interface, can be customized multimeter special interface

Selection Guide

ModelXtester-PT-740Xtester-PT740-1AXtester-PT740-2AXtester-PT740-3A
Range Peak 0.2A-30A  |  30A-300A 0.2A-40A  |  40A-400A 0.2A-60A  |  60A-600A 0.2A-140A  |  140A-1400A
Range DC 0.4A-30A  |  30A-300A 0.4A-40A  |  40A-400A 0.4A-60A  |  60A-600A 0.4A-140A  |  140A-1400A
Output signal ratio 10mV/A(100:1)|1mV/A(1000:1) 10mV/A(100:1)|1mV/A(1000:1) 10mV/A(100:1)|1mV/A(1000:1) 10mV/A(100:1)|1mV/A(1000:1)
Accuracy1.5%±5mV
Noise1mV rms
Rise/Fall time2.3us
Reference conditions18℃-28℃, 20-75%RH, sinusoidal frequency 48Hz-65Hz, external magnetic field < 40A/m, no DC component, no AC carrier nearby, central test sample, load impedance ≥1MΩ and ≤100pF, DC-65Hz before measurement reset to 0, battery 9V±0.1V
BandwidthDC-150kHz(-3dB)
Load impedance≥1MΩand≤100pF
Input impedenceWhen 50Hz, 0.39MΩ, When 1000Hz, 58MΩ
Working VoltageThe lagrest 600V rms
Influence of adjacent conductorsWhen 50Hz, <10mA/A
Influence of the Position of the jaw conductor0.5% reading
Battery/Battery life9V alkaline battery/approx. 50 hours
(Battery capacity indication) (Overload indicator)When >6.5V,Green LED light (Red LED light is overload indicator)
Automatic shutdown time10min
DC zero adjustment
Jaw size insert conductor1 cable: diameter 30mm; 2 cables: 24mm diameter or 2x 31.5x 10mm bus cable
Size/Weight/Color224x97x44mm/440g/ Dark grey box :; Red frontal orifice
OutputLine length 2M,BNC interface, can be customized multimeter dedicated interface
Temperature and humidity0-50C / 20-75% RH


Telephone
Email
Map
QQ Chat